FAUCET INSTALLATION
STEP 3 – CONNECTINg ThE POwER SOURCE
IMPORTANT: This product includes a self
adjusting sensor.
The ideal sensor range for the specific
location will be set automatically.
Connect the connectors between
1
the solenoid valve and the
electronic unit.
For battery versions:
Install the battery box on the wall
in the mirror compartment and
connect the battery connector.
2
For transformer versions:
Plug the transformer into the
electricity socket and make sure
the transformer connector is
connected to the sensor.
wait about 10 seconds before you
3
put your hands within the sensor
range.
If the automatically adjusted sensor range is not satisfactory to your
purposes, please refer to the section entitled "Settings adjustment" .
6
SETTINgS ADJUSTMENT
Before
proceeding,
check that
no objects
are in front
of the sensor
besides the
washbasin.
Adjusting the settings with the remote control
If necessary, the sensor settings can be adjusted as following:
Shut off the water supply. In order to adjust the sensor with the remote control,
hold the remote control straight in front of the sensor in a distance of about 6-8"
10
(15-20cm). Choose the function you want to adjust by pressing once on one of
the function buttons. After pressing once on a specific function button, a quick
flashing of the LED at the front of the sensor will occur. At this stage, you can
SECONDS
change the setting by pressing the (+) or the (-) buttons, every push will increase or
decrease one level. After finishing the adjustment, turn the water supply back on.
DETECTION
RANgE
DELAY IN TIME
SECuRITY TIME
COMFORT FLuSH
DELAY OuT TIME
TEMPORARY OFF
FuNCTION
SELF ADJuSTMENT
MODE
RESET
HYgIENE FLuSH
7