– Do not remove all the callus skin in order to retain the natural protection of the
skin.
– Always ensure that the spindle can rotate freely. It must never be permanently
jammed, otherwise the instrument will become too hot and suffer damage.
– After every use, apply moisturizing cream to the parts treated.
Important:
Check the results during treatment. This is particularly important for
diabetics, since their hands and feet are less sensitive.
3.2 Attachments
Since the attachments are of a high quality and improper use can lead to injury,
we ask that you handle the attachments carefully. At high speeds in particular,
we advise that you proceed with caution.
The following attachments are included:
A – Sapphire cone
Removal of dry skin or calluses from the soles of the
feet and from the heels and for manicuring the nails.
B – Felt cone
Smoothing and polishing the edge of the nail after
filing as well as for cleaning the nail surface. Always
polish in circular movements and do not allow the
felt cone to rest in one place, otherwise friction could
cause heat to develop.
C – Sapphire disk, fine
Filing and treatment of the nails, fine grained sapphire
disk.
The specific aspect of this sapphire disk is that only
the inner disk rotates, while the outer support is sta-
tionary. This enables precise filing of the nails without
the risk of burning the skin with the fast rotating disk.
D – Cylindrical milling cutter
Grinding of lignified foot nail surfaces as well as
smoothing of these. For this purpose, apply the milling
cutter horizontally to the nail surface and remove the
unwanted layer of nail using slow circular movements.
100127_MEDEL BD MANICURE PEDICURE EXPERT 95157_REV.01_05.06.17.indd 14-15
14
E – Flame milling cutter
For removing ingrowing nails. Carefully guide the
flame cutter up to the part to be treated and remove
parts of the nail as necessary.
F – Sapphire milling cutter, round
This accessory attachment is for the careful removal
of corns. When using this attachment, please remem-
ber when removing the layer of skin from the corn
that you will quickly penetrate deeper into the skin
and this could injure the periosteum.
When filing, always work from the outside of the nail towards the tip!
Always check results regularly during treatment. As soon as the application
becomes unpleasant, stop the treatment.
4. Cleaning
Before cleaning the power unit, always unplug it from the socket outlet!
– Clean the instrument with a slightly moistened cloth. You can also moisten the
cloth with mild soap suds to remove more stubborn dirt.
– If necessary, for reasons of hygiene, the attachments can be cleaned with a
cloth or brush moistened with alcohol. Dry them carefully afterwards.
– Do not drop the instrument.
– Make sure that no water enters the instrument. But if this should happen, do
not use the instrument again until it is completely dry.
– Do not use chemical detergent or scouring agents for cleaning.
– Never immerse the instrument or plug-in power unit in water or other liquids.
5. Disposal
Please dispose of the device in accordance with EC Directive – WEEE
(Waste Electrical and Electronic Equipment).