3.
INSTALLATION AND ASSEMBLY
GENERAL
• Assembly and installation of our pumps is only permitted in swimming pools
or tanks complying with regulation HD 384.7.702. In case of doubt please
consult a technician.
• All pumps come with a two-drill foot to allow it to be fixed to the floor by
means of an anchor. (Fig. 1).
TUBING
• The connection of the pipes must be threaded to the outlets of the pump.
(Fig.2)
• Impulsion tube installation is done totally perpendicularly and is well centred
with respect to the nozzle to be connected so as to avoid external pressure
being exerted on the pump and the tube. Apart from making assembly more
difficult, this pressure could even break them. (Fig. 2)
• Suction tube installation is done at a slight angle of 2 % towards the pump,
thus avoiding siphon formation. (Fig.2).
• For a correct operation, the pump must be primed until water rises from the
suction tube.( Fig.3)
19
Fig. 1
Fig. 2