8. Maintenance
1.
You must check both the entire length of the steel
cable (13) for damage and the proper working
condition of the limit switch (5) at regular intervals
(wind up the cable winch until the switch-off
weight (12) actuates the switch-off lever (3)).
2.
If the steel cable (13) is damaged (kinked or
splayed, see Fig. 4) it must be replaced by a
genuine replacement part. Have the cable repla-
ced at a qualified workshop. When the cable is fit-
ted it is imperative that the switch-off weight (12),
for reliable limit stopping, is not forgotten.
3.
You should apply a little oil to the bearing of the
return pulley (14) at regular intervals.
4.
Check the smooth running of all the mechanical
parts of the winch with the equipment switched
off.
5.
The device must be inspected by a qualified per-
son at least once a year. The results of the ins-
pection must be recorded in an inspection book.
18