If the unit is not working properly, this may be due to small problems that you can easily resolve yourself.
Follow these instructions carefully before contacting your local Authorised Technical Service Centre.
PROBLEM
The unit does not
work
The unit works for
only a short time
The tank full light is
on
The unit works but
does not cool the
room

TECHNICAL ASSISTANCE

Keep the list of Technical Service Centres and
identify the one nearest to you.
RECOMMENDED OPERATING CONDI-
TIONS
Room temperature:
Outside temperature:
Pagina 13

Troubleshooting

CAUSE
there is no electricity
it is not plugged in
the function selector is in the "•" position
the timer pin is in the 0 position or it is not pro-
grammed to operate at that moment
there is a kink in the outlet tube
the outlet tube is blocked
there are too many curves in the outlet tube
the fan is blocked
the tank is full activating the safety float
the tank is incorrectly positioned
three minutes have not passed since it was
turned on
windows open
a heat source is operating in the room (bur-
ner, light, etc.) or there are a lot of people
the air outlet tube has come detached
from the coupling
thermostat adjusted too high
air filters clogged
the output of the unit is insufficient for the
conditions or size of the room
69-90°F
69-109°F
REMEDY
wait
plug in
move the selector to the desired
position
set the timer to the required
mode (see turning on the unit and
programming the timer)
position the outlet tube correctly
check there are no blockages
preventing the discharge of air
to the outside
rearrange the tube correctly
(see set up instructions)
contact the Service Centre
empty the tank
reposition the tank correctly
wait three minutes (safety devi-
ce)
close the windows
eliminate heat sources
fit the tube in the coupling
lower the thermostat
clean/replace filters

TECHNICAL SPECIFICATION

Power supply
Max. absorbed power
in air conditioning
Refrigerating capacity*
7500btu/h - 2200W
Number of fan speeds
Max. air flow .
Dimensions of internal unit:
• width
• height
• depth
• weight
*
At ASHRAE 128 P conditions
see rating plate
"
2
272 cfm
17,95"
31,50"
16,34"
75 lbs.
13