model B-715,115V AC, 15 Amp, 1725 Watts, 60 HZ, Single Phase, cULus listed.
model B-715e, 220-240V, 7A, AC 1500-1700 Watts, 50/60 Hz, Single Phase; VDE approved and, CE marked.
B-715e is not available in the united states and canada.
Installation instructions and template provide information that will assist in the installation of the Bobrick B-715 115V, B-715E 220-240V. Retain
Installation Instruction Sheet for important maintenance instructions and warranty information.
Distance from floor to bottom mounting screw holes of mounting base.
Men's Washrooms ....................................................................................................................................................................46''
Women's Washrooms ...............................................................................................................................................................44''
Children's Washrooms, ages 3-9 .............................................................................................................................................32''
Children's Washrooms, ages 9-12 ............................................................................................................................................36''
Children's Washrooms, ages 12-15 ..........................................................................................................................................40''
Children's Washrooms, ages 15-18 ..........................................................................................................................................44''
Barrier-Free Design ..................................................................................................................................................................38''
*
Bobrick automatic hand dryers should be installed 15" (380mm) above any projection or horizontal surface which may interfere with the operation of
the automatic sensor.
*
Warm air hand dryer. intended for use in a household environment by non-expert users. Not suitable for outdoor use.
**
this appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved. children shall not play with the appliance.
cleaning and user maintenance shall not be made by children without supervision.
***
if a fault develops disconnect the electrical supply, a qualified electrician should be called.
1. Start installation of dryer by removing cover. Remove three screws, one from each side and one from the bottom of the dryer. Lift the cover from the
mounting base.
for ProPer eLectricAL coNNectioNs, checK LocAL BuiLdiNG code. uNit must Be iNstALLed By A QuALified LiceNsed
eLectriciAN
1. Hold the Installation Template against the wall in the desired location of the installed
dryer, see recommended mounting heights above.
2. Make sure line on template representing bottom of dryer mounting base is
horizontal and located at the desired height above floor.
3. Mark center of four mounting screw holes and hole for entry of electrical wiring if
electrical supply is concealed in wall and will enter dryer from back through
mounting base.
NOTE: Surface-mounted electrical supply entry is located in the lower right corner
of the mounting base. Bottom of mounting base has 1/2'' square (13mm) opening in
lower right corner to accommodate connection of electrical conduit.
4. Drill four holes for #10 (M4.8) mounting bolts or screws (not furnished).
5. For masonry walls provide four #10 expansion shields or anchors and secure
with four #10 (M4.8) sheet-metal screws (not furnished). For plaster or dry wall
construction, provide concealed backing to comply with local building codes and
secure with four #10 (M4.8) round-head sheet-metal screws, or 3/16'' (5mm)
toggle bolts (not furnished).
NOTE: Use 2'' (50mm) long screws in top two mounting holes. Use 3'' (75mm) long
screws in lower two mounting holes.
6. Fasten mounting base securely to wall.
Form No. 715-69 Multi Language (Rev. 7-12-13)
2

Electrical Characteristics

Recommended Mounting Heights

Important
Removal of Cover
Installation of Mounting Base
8-1/16''
(205mm)
Horizontal
Reference
WArNiNG: turN eLectricAL PoWer suPPLy off Before
mAKiNG eLectricAL coNNectioNs. dryer must Be
© 2013 Bobrick Washroom Equipment, Inc.
(1170mm)
(1120mm)
(815mm)
(915mm)
(1015mm)
(1120mm)
(965mm)
Mounting Base
C
3-15/16''
(100mm)
3-17/32''
7-7/8''
(90mm)
(200mm)
4-11/32''
(110mm)
7/8''
(22mm)
Ø3/4''
(Ø18mm)
Entry Hole for
Between-Wall Wiring
5/8''
(16.5mm)
Entry Point for
Surface Mounted Wiring
4-17/32''
(115mm)
GrouNded (eArthed).