Installation instructions
Installation
These instructions are aimed at qualified fitters as a
guide to installation, adjustment and maintenance in
compliance with the laws and standards in force. The
operations must always be carried out with the
appliance disconnected from the electricity supply.
Positioning (Fig. 8-9-10-11)
The appliance is made to be fitted into a counter top, as
show in the figure. Apply the sealant supplied around the
whole perimeter of the hob. Installation over an oven is not
recommended, but if this is necessary, check that:
- the oven has an efficient cooling system;
- there is no passage of hot air from the oven to the hob;
- allow air passages as shown in the figure 10.
Electrical connection (Fig. 12-13)
Before connecting to the electricity supply, ensure that:
- The supply voltage marked on the rating plate
located under the hob corresponds with your mains
supply.
- the system has an effective earth connection
compliant with the standards and laws in force.
Connection to earth is compulsory by law.
Mod. BHI400SS
Fig. 8
380
INDUCTION
INDUCTION
If the appliance has no cable and/or plug, use a
cable suitable for the absorption indicated on the
registration plate and for the working temperature. The
cable must not reach a temperature higher than 50°C
above room temperature in any point.
For direct connection to the electrical supply it is
necessary to fit an omnipolar switch of a suitable size to
ensure disconnection of the electrical supply with a
contact opening distance that allows complete
disconnection in the conditions of the overtension
category III, compliant with the installation regulations
(the yellow/green earth wire must not be interrupted).
The omnipolar socket or switch must be easy to reach
when the appliance is installed.
N.B.:
- The manufacturer declines all responsibility if the
usual accident prevention standards and the above
instructions are not observed.
If the power cable is damaged, it must be replaced by the
manufacturer or by the manufacturer's technical servicing
network, or by a similarly qualified operator, to prevent
every possible risk.
Diagram below shows
both flush and proud
mounting
cut-out
dimensions.
+1
381
0
+1
360
0
19
GB