To program the desired temperature, press ON/OFF + ▲ or ▼ buttons.
To lock the keyboard again proceed as stated above and select "YES" in the "LOC" function.
The display will indicate the temperature of the cabinet.
N.B.: The differential has been regulated at 4ºC in the plant.
When loading the refrigerator in its totality it is possible that the alarm begins to ring after 2 hours if the refrigerator has not
reached yet the programmed temperature. Push any button to turn off the buzzer and await 12 hours for stabilization of the
temperature. In case the programmed temperature has not been reached in this space of time, contact our technical
services.
4.3- Defrosting
Defrosting is automatic, (only occur if it's necessary because is controlled by evaporator temperature and finish by
temperature, isn't necessary the 30 minutes) and controlled by a digital thermostat. The cycle is pre-programmed in the
plant to act every 6 hours during 20 minutes. The condensation water is automatically re-evaporated. Make sure that the
draining outlet isn't blocked. (Models without group connecting the branch tube in drainage sewer.)
Operating messages
Message
E0
E1
LO
HI
DF
OFF
The manufacturer isn't responsible for damage caused by installation or connection errors
An installation error could cause serious harm to persons, animals or others for which the manufacturer accepts no
liability.
5.
Maintenance
Keep the equipment clean and avoid dust or other materials accumulating in the ventilation grilles.
The maintenance operations must be done by the manufacturer, its service agent or similarly qualified persons in order to
avoid hazard.
6.
Replacing the lighting
Led strip. The power of the illumination is 12 W/m. Power 12 V DC.
The replacing operations should be done by the manufacturer, its service agent or similarly qualified persons in order to
avoid hazard.
7.
Breakdowns
7.1 – The appliance is not working
Check whether there has not been a power cut.
Check whether the plug is energized.
Check whether the plug is properly connected.
Check the switch position.
7.2- The appliance is working but only becomes slightly cold
Check the thermostat programming.
Check the ice accumulation on the evaporator.
Check whether the door is properly closed.
7.3- Water appears at the bottom of the refrigerator
Check whether the emptying outlet is blocked or whether the emptying tube is not pointing towards the evaporation tank in
the compressor department.
Check the refrigerator level.
7.4 – The supplier cable is damaged
If the supply cord is damaged gets damaged, it must be replaced by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
If, after making these checks, the anomaly remains, you should ask your retailer for assistance or contact our technical
department directly.
In the latter case, you should indicate:
The nature of the failure, the number and type of the appliance and the purchase date (certificate of warranty).
15.05.2018
Description
Faulty ambient sensor
Faulty defrosting sensor
Low temperature alarm
High temperature alarm
Defrost
Standby