Descargar Imprimir esta página

KEUCO Edition 90 59027 010100 Instrucciones De Instalación página 4

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 5
EN
These instructions are for both the installer for
installation and the user for operation and main-
tenance of the product. After installation, please
hand them over to the user to keep.
Symbols and explanations
Attention! Warning against bodily injury or
damage to property.
Note, tip or reference
Correct installation/test of functionality
Incorrect installation
Observe installation details
Cold water
Water fl ow
Intended use
Single lever mixer tap for use in bathrooms.
Operation possible with pressure tanks and ther-
mally and hydraulically controlled instantaneous
water heaters. Operation with unpressurised
tanks (open water heaters) is not possible!
Operation only with potable water.
Product is only suitable for installation indoors!
Attention! Only install in frost-free places.
4
Important information, please read!
Hot water
No water fl ow
Technical specifi cations
– Flow at 3 bar pressure
- bath fi ller/spout:
- hand shower:
– Pressure:
min. 0.5 bar/recommended 1-5 bar
– Operating pressure
– Test pressure:
– Recommended hot water inlet temperature:
– Water connection:
Avoid pressure differences between the cold and
hot water feeds.
Install a pressure reducer for static pressures
above 5 bar.
Installation dimensions, refer to page 2
Installation, refer to picture 1 on page 12
Flush potable water pipes thoroughly before and
after installation (observe EN 806 and 1717, as
well as DIN 1988).
Use only neutrally netting silicone.
Test connections for leaks with water pressure.
Operation, refer to picture 10 and 11 on page 13
Temperature controll, refer to picture 12 on page 13
Assemble in reverse order.
Servicing, refer to picture 13 and 14 on page 14
Assemble in reverse order.
– Cartridge nut torque:
For spare parts with order numbers, refer to page 15.
For warranty and care information please refer
to the attached warranty and care instruc-
tions.
approx. 20 l/min
approx. 10 l/min
max. 10 bar
16 bar
max. 65°C
cold = blue marking
hot = red marking
12 Nm

Publicidad

loading