Manual Mode - Health Zenith Secure Home DualBrite 4266 Instrucciones De Instalación Y Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4. Move the sensor head left or right to change
the coverage area. Note: Grasp the sensor only
as shown and turn the entire sensor. Any other
method may damage the sensor. Do not
force it past the stops.
Rotating Sensor Head to Change Coverage Area
5. Adjust the SENSITIVITY to increase or
decrease the range as needed. Too much sen-
sitivity may cause false triggering due to heat
sources in the coverage area (see Adjustment
of Coverage Area or Troubleshooting section).
6. Set the amount of ON-TIME you want the
light to stay on after motion is detected (1, 5,
or 10 minutes).
7. Set the DualBrite® switch to off, 3 hours, 6
hours, or dusk-to-dawn.
6 ft.
(1.8 m)
(9.1 m)
Maximum Range
30 ft.
Maximum
Coverage Angle
(Top View)
The sensor is less sensitive to motion directly
towards it and more sensitive to motion across
coverage area.
Motion
Least Sensitive
Mode:
Test
Auto
Accent
Manual
* resets to Auto Mode at dawn.
Note: W hen first turned on wait about 1
for the circuitry to calibrate.
Manual mode only works at
night because daylight returns
the sensor to AUTO.
Flip the light switch off for one
second then back on to toggle
between AUTO and MANUAL
MODE.
Manual mode works only with
the ON-TIME switch in the 1,
5, or 10 position.
150°
6
Sensor
Most Sensitive
OPERATION
On-Time
Works: Day Night
5 Seconds
1, 5, or 10
Minutes
3, 6 Hour,
To Dawn
To Dawn*

MANUAL MODE

Motion
x
x
x
x
x
/
minutes
1
2
1 Second
OFF then...
... back on.
200254-02