3.4. TIPS AND RECOMMENDATIONS FOR USE
3.4.1. Questions about the Oximo WireFree™ battery?
Observations
The roller shutter is not operational.
The roller shutter stops briefly before rising, when
the Up button is pressed.
The roller shutter performs two brief movements
in the same direction, when the Down button or
STOP/my button is pressed.
The battery is recharged several times a year using
the external battery charger.
3.4.2. Recharging and replacing the battery
To recharge or replace the Oximo WireFree™ battery, contact a motorisation and home automation professional.
.
Please separate storage cells and batteries from other types of waste and recycle them via your local collection facility.
4. TECHNICAL DATA
Power supply
Capacity
Operating temperature
Index protection rating
Max. charging time
Charging frequency
Max. storage time (before first charge)
Maximum charge current
Copyright © 2017-2018 SOMFY ACTIVITES SA, Société Anonyme. All rights reserved.
Possible causes
The wiring is incorrect.
The battery is low.
One of the components (motor,
solar panel, control point, etc.)
is not working.
The battery is low.
The battery is low
The solar panel is incorrectly
positioned.
The solar panel is defective or
damaged.
The battery has reached the end
of its service life.
6 months at 20°C. After storage for this period, there is a risk that the battery
Black wire
Red wire
Solutions
Check the wiring and modify it if necessary.
Check that the connection between the motor and the
battery has been carried out correctly.
Wait while the solar panel recharges the battery, or have
the battery recharged.
See the corresponding guides.
Wait while the solar panel recharges the battery, or have
the battery recharged.
Check the location of the solar panel; see the Somfy
solar panel guide.
Replace the solar panel; see the Somfy solar panel
Replace the battery.
12 V DC
2.2 Ah
- 20°C to + 70°C
IPX4
3.5 hrs.
Max. 2 per year.
may be completely discharged.
200mA
–
+
EN
guide.