Dear Customer,
compliments on your purchase: this IMER mixer, the result of long-stan-
ding experience in the fi eld, features maximum reliability and innovative
technical solutions.
- WORKING IN SAFETY
To work in complete safety, read the following instructions careful-
ly before using the machine.
This OPERATION AND MAINTENANCE manual must be kept by the
Site Manager and be always available for consultation.
The manual is considered part of the machine and must be stored for
future reference (EN 12100-2) through to scrapping of the machine it-
self. Should the manual be lost or damaged, a replacement copy can be
ordered from the manufacturer.
The manual contains important information regarding site preparation,
machine use, maintenance procedures, and requests for spare parts.
Nevertheless, the installer and the operator must both have adequate
experience and knowledge of the machine prior to use.
In order to ensure operator safety, safe operation and long service life,
it is imperative to adhere to the instructions set out herein and the re-
quirements of the legislation in force governing safety in the workplace.
Use individual safety equipment (suitable shoes and clothing, gloves,
safety glasses, etc.).
- Make sure that all signs are legible.
- It is strictly forbidden to carry out any form of modifi cation to
the steel structure or working parts of the mixer.
IMER INTERNATIONAL accepts no liability for failure to comply with
laws governing the use of this type of equipment, with particular refe-
rence to: improper use, incorrect power supply, lack of maintenance,
unauthorised modifi cations, failure to comply, either wholly or partially,
with the instructions set out in this manual.
IMER INTERNATIONAL reserves the right to modify features of the mi-
xer and contents of this manual, without the obligation to update pre-
vious machines and/or manuals.
1. TECHNICAL DATA
Technical data are stated in table 1 and electrical specifi cations in table
2.
Table 1 - TECHNICAL DATA
Model
Drum capacity
Mix capacity (approx.)
Paddle rpm
Paddle rotation direction
(view from loading mouth)
Wheel dimensions
Single phase motor power
Overall dimensions
(width x length x height)
Machine weight
Weight with packaging
Table 2
Motor
Feature
(230V/50Hz)
Power (kW)
1.4
Rated voltage (V)
230
Frequency (Hz)
50
Absorbed current (A)
9
Number of poles
2
rpm
2800
Service type
S1
Insulation category
F
Protection category
IP55
Capacitor (μF)
50 (Ø 55x94)
IMER INTERNATIONAL S.p.A.
MIX 120 PLUS
MIX 120 PLUS
120 l
60 l
38 Rpm
Clockwise
300 mm
1.4 kW
780x880x1000 mm
130 Kg
139 Kg
Motor
Motor
(230V/60Hz)
(110V/50Hz)
1.4
1.4
230
110
60
50
9.4
15
2
2
2800
2800
S1
S1
F
F
IP55
IP55
50 (Ø 55x94)
100 (Ø 50x120)
11
2. DESIGN AND CONSTRUCTION STANDARDS
The MIX 120 PLUS mixer is designed and constructed in line with the
following harmonized standards: EN 12151:2008; EN 12100-1/2:2005;
EN 60204-1:2006.
3. NOISE LEVEL AND VIBRATIONS
Table 3 gives the sound pressure level of the machine measured at the
ear of the operator when running empty (LPA) and vibrations transmitted
when it is operating.
Table 3
Model
Type of motor
MIX 120 PLUS
Electric
4. DESCRIPTION AND OPERATION
- The mixer is intended for use on construction sites for
mixing a wide range of fi ne grained materials, both wet and dry,
premixed in bags or drawn from silos, of low and high viscosity
(mortar, paints, plaster, cement, adhesives, resins, coatings, vibra-
tion-damping materials, insulation).
- Do not use the machine in environments subject to tempe-
ratures below 0° C.
The mixer is composed of a frame (ref.1, fi g.1) which supports the mi-
xing tank (ref.2, fi g.1).
The tank mounts the gear reducer (ref.6, fi g.1) driven by the motor (ref.5,
fi g.1) via a poly-V drive belt.
The reducer's output shaft delivers the drive to the mixer head).
The tank can be emptied by opening the outlet (ref.7, fi g.1) by hand.
The motor is started and stopped with the switch on the electrical cabi-
net (ref.8, fi g.1).
The electrical cabinet has a plug (ref.9, fi g.1) for connecting to the elec-
tric power supply.
5. SAFETY MEASURES
The IMER mixer is designed to operate on construction sites and is not
equipped with its own lighting; the work site must be well illuminated
(min. 300 lux).
- Never use the machine in areas at risk of explosion/fi res.
1. The IMER mixer will only run if all its safety devices are in place
and in perfect condition.
2. Do not use improvised and/or defective power supply lines.
3. The connection lines on the site must be laid in such a way that
they cannot be damaged. Never stand the mixer on its power sup-
ply cable.
4. The plug/socket connections must be protected from water.
Use only connectors equipped with protection against water jets
(IP67).
5. Repairs to the electrical installation must be performed exclu-
sively by specialised personnel. Do not make any adjustments or
carry out any maintenance work while the machine is powered up
or running.
- Never put your hands or tools into the tank while the machine
is running.
- Take care, when handling mix components, not to raise dust
which may be inhaled. If this is not possible, masks must be worn
to protect the mouth and nose.
- To stop the mixer, use the switch (ref.8, fi g.1). Do not attempt
to stop the mixer in any other manner.
6. ELECTRICAL SAFETY
The IMER mixer is constructed in line with the provisions of EN 60204-1,
and is protected against jets of water (IP 55) and equipped with protec-
tions against overloads and automatic restarting after power failures.
7. MECHANICAL SAFETY
The hazardous points on the IMER mixer are protected by means of
safety devices, which must remain fi tted at all times and kept in perfect
condition - as, for instance, the drive belt guard.
The tank is fi tted with a guard which enables mix components to be loa-
ded into it while preventing access to the mixing area (ref.10, fi g.1).
The machine is equipped with an electrical safety (interlock) which pre-
vents it from running when the mixer tank guard is open.
GB
L
A
pA
eq
86 dB
2 m/s
2