Scrolling text
 
 
  
  

  
  
 
 
 
 
 
  
  
Note:
When the charger is not active (night time) the bulk, absorption and float icons will be shown
as in the table above.
When the charger is active only one icon will be shown: the icon corresponding to the actual
charge state.
3.12 Pluggable LCD display - Setup menu
a. To enter the SETUP Menu, press and hold the SETUP-button during 3
seconds. The "Menu" icon will light up and a scrolling text is visible.
b. Press the "-" or "+" button to scroll through the parameters.
c. The table below lists, in order of appearance, all parameters which can be
adjusted by pressing the "-" button.
d. Press SELECT: the parameter to change will now blink.
e. Use the "-" or "+" button to chose the desired value.
f. Press SELECT to confirm the change, the value will stop blinking, and the
change is made final.
g. Press SETUP to return to the parameters menu. With the "-" or "+" button
it is now possible to scroll to another parameter that needs change.
h. To return to normal mode, press SETUP during 3 seconds.
12
(1)
Icons
Segments Units
.
kWh




.
V
.
V
.
Day kWh Daily yield
.
Day V
.
Day V

Day

Day

Day

Day


Day


Day


Day

Day W
.
Day A
.
Day V
Displayed info
Total yield
Total error 0 (most recent)
Total error 1 (shown when available)
Total error 2 (shown when available)
Total error 3 (shown when available)
Total panel voltage maximum
Total battery voltage maximum
Daily battery voltage maximum
Daily battery voltage minimum
Daily error 0 (most recent)
Daily error 1 (shown when available)
Daily error 2 (shown when available)
Daily error 3 (shown when available)
Daily time spent in bulk or ESS (minutes)
Daily time spent in absorption (minutes)
Daily time spent in float (minutes)
Daily power maximum
Daily battery current maximum
Daily panel voltage maximum