The unit is supplied with a photocell connected and configured to switch the lamp on when light
levels fall below 25 lux. If you want the lamp to run continuously or to use an alternative switching
source please refer to the section 'Remote Switch Inputs'.
Feed mains cable through lower gland
and fasten to post with cable tie provided
Feed illuminator cable through upper
gland and secure to photocell wiring
using cable ties provided
2025 Installation Manual
Connect mains into terminal block green/yellow
to earth, brown to live ('L') blue to Neutral ('N')
Connect illuminator cable to terminal block,
observe correct polarity
Figure 7 – Customer wiring
Page. 10