UK
The boxed numbers (e.g.
Fully illustrated step by step instructions are
downloadable on www.saniflo.co.uk
1
DESCRIPTION
This pump/macerator has been designed to pump away the
waste from a WC and the sanitary appliances mentioned in fig
. SANIBEST Pro
n°
®
is a robust machine which is capable
1
of handling occasional sanitary article accidentally flushed
down the WC. Installed and used correctly, SANIBEST Pro
will give consistent and reliable service.
Please note the following warning signs:
«
» Possible danger to personnel,
«
» Warning of possible electrical hazard,
«
» Instructions for use only by qualified professionals,
«WARNING» This is a general warning that failure to
follow instructions could result in poor functioning
of the unit.
2
LIST OF ACCESSORIES INCLUDED
3
DIMENSIONS
4
TECHNICAL DATA
Application
Type
Vertical Pumping
Voltage
Frequency
Normal Power Rating
Maximum current consumption 5 A
Electric Class
Degree of protection
Net Weight
WARNING:
Only installations conforming to the above
specifications are acceptable.
5
PERFORMANCE CURVE
6
VERTICAL/HORIZONTAL PUMPING
COMBINATIONS
7
INSTALLATION
WARNING:
The unit must be connected to a WC pan with
horizontal outlet spigot conforming to EN33 or EN 37 norms.
The SANIBEST should be installed so that it is accessible
for possible maintenance
The macerator has fastenings preventing it turning or from
floating.
7a
CONNECTION TO A WC
1 - Pull flexible sleeve over the pan entry spigot of the
machine.
2 - Fix with the cable tie supplied.
3 - Fix the hose clip around the flexible sleeve,
then pull the sleeve over the pan exit spigot
4 - Position the hose clip at the edge of the flexible sleeve
and tighten the hose clip with a screwdriver.
7b
CONNECTION OF THE DISCHARGE PIPEWORK
1 & 2 - See fig. 7b.
1
) refer to the explanatory diagrams and the circled numbers (e.g. 7a ) refer to the scatter diagram on the last page.
1 WC + + shower
+ bidet + washbasin
B85
max. 7 m
220-240 V
50 Hz
1100 W
I
IP44
10 kg
3 - Orient the assembly as required and push it well into
the black rubber pipe 7 . Fix the base of the elbow in
place with a collar
4 - Cut off the end of the sleeve, if necessary, to suit the
diameter of the discharge pipe and use a collar
WARNING:
Protect pipes against freezing with appropriate
insulation. If the toilet is installed in an unheated location
during freezing periods protect it as follows:
• Shut off the water supply,
• Activate one cycle without water,
®
• Pour antifreeze in the bowl (2 litres),
• Flush the toilet.
WARNING:
Any bends in the discharge pipe run should be
smooth radius bends. If using plastic pipe two 45 degree
offsets can be used to form a smooth bend.
NOTE:
We would recommend that a drain-off point is ins-
talled to allow the discharge pipework to be drained down
before any service work.
NOTE:
To avoid siphoning, install a an anti-siphon valve at
the high point of the installation.
5 - We advise installing a drain valve at the low point to
facilitate maintenance.
6 - If the end of the discharge pipework is much lower than
the unit, install a riser pipe about 80mm long from the
highest point of the discharge run and fit an air admit-
tance pipe on top (capable of withstanding at least
15psi pressure.) to break the syphon.
End the outlet pipe at the waste stack.
• All horizontal piperuns require a 1:100 fall.
• If a vertical lift is required, this must be installed at the
start of piperun and a 1:100 fall given to the pipe from
the high point to the drain.
• All bends should be smooth/slow (eg pulled bens or
2 x 45 degree bends together). Do not use 90° elbows.
• If the horizontal piperun exceeds about 10 metres, increase
the size from 22 mm to 32 mm from that point onwards.
7c
CONNECTION OF THE OTH ER SANITARY APPLIANCES
1 - To connect to the side entries of the case, use the
rubber connector
2 - Plug the unused inlet with blanking plug
greasing the joint.
WARNING:
Ensure when connecting a shower to
SANIBEST Pro
®
that the underside of the shower tray is
raised by at least 15cm from the floor.
7d
CONNECTION OF A WASHBASIN
The washbasin can be connected in two ways.
To one of the side inlets (see
Or to the raised inlet that can be cut open on the cover.
To do so:
• Cut off the top of the raised inlet with a saw.
• Do not leave any sharp angles on the edge of the cut.
Remove any burrs.
• Connect the rubber connector
• Insert the Ø 32 mm waste pipe from the washbasin
into the sleeve (clips
7e
VENTING
SANIBEST Pro
®
is fitted with an active carbon filter, and
requires no external venting.
7f
EXAMPLE OF SANIBEST Pro
7g
ELECTRICAL CONNECTION
The electrical installation should be carried by a
qualified person and conform to BS 7671 1992
requirements for electrical installation.
The unit requires a 220/240V single phase AC 50 Hz supply
(UK specification). Do not connect the unit to a conventional
plug and socket.
8
D
.
C
. Secure with clips
D
and
F
7c
)
to the raised inlet.
C
supplied).
D
' INSTALLATION
®
E
or
J
.
E
.
after