INSTALLATION
STEP
6
Install
the Door Control
Locate door control within sight of door, at a
minimum height of 5 feet (1.52 m) where small
children cannot reach, away from moving parts of
door and door hardware. If installing into drywall, drill
5/32" holes and use the anchors provided. For
pre-wired installations (as in new home
construction), it may be mounted to a single gang
box (Figure 2).
1. Strip 1/4" (6 mm) of insulation from one end of bell
wire and connect to the two terminal screws on
back of door control by color: white to 2 and
white/red to 1.
2. Pry off cover along one side with a screwdriver
blade (Figure 1). Fasten with 6ABx1-1/4"
self-threading screws (standard installation) or
6-32x1" machine screws (into gang box) as follows:
• Install bottom screw, allowing 1/8" (3 mm) to
protrude above walt surface.
• Position bottom of door control on screw head
and slide down to secure. Adjust screw for snug
fit.
• Drill and install top screw with care to avoid
cracking plastic housing. Do not over tighten.
• Insert top tabs and snap on cover.
3. (For standard
installation
only) Run bell wire up
walt and across ceiling to motor unit. Use
insulated staples to secure wire in several places.
Be careful not to pierce wire with a staple, creating
a short or open circuit.
4. Connect the bell wire to the terminal screws on the
motor unit panel: white to 2; white/red to 1.
5. Position the antenna wire as shown.
NOTE: DO NOT connect power and operate opener
at this time. The trolley will travel to the full open
position but will not return to the close position until
the sensor beam is connected and properly aligned.
To prevent possible SERIOUSINJURYor DEATHfrom
electrocution:
• Be sure power is not connected BEFORE installing door
control.
• Connect ONLYto 24 VOLT low voltage wires.
To prevent possible SERIOUSINJURYor DEATHfrom a
closing garage door:
• Install door control within sight of garage door, out of
reach of children at a minimum height of 5 feet
(1.52 m) and away from all moving parts of door.
• NEVERpermit children to operate or play with door
control push buttons or remote control transmitters.
• Activate door ONLYwhen it can be seen clearly, is
properly adjusted, and there are no obstructions to door
travel.
• ALWAYSkeep garage door in sight until completely
closed. NEVERpermit anyone to cross path of closing
garage door.
Outside Keylock Accessory Connections
I ToO lo.pener terminal screws: white to 2; white/red
HARDWARE
SHOWN ACTUAL
SIZE
Control Console (std installation)
_r
_
Insulated
Staples
Control Console (we-wired)
Dry Wall Anchors
Figure 1
REMOVE & REPLACE COVER
To Replace,
To Remove,
Insert Top
_ /
Twist
Tabs_; _ First _,
Here
Figure 2
PRE-WIRED
INSTALLATION
24 Volt
2-Conductor
Bell Wire in
Gang Box
Lighted
PushButton
\
Opener
2_"-Conductor
Terminal Screws
BellWire
PREMIUM
CONTROL CONSOLE
Light
Top
Lock
Mounti_J
Terminal
Bell
Bottom
Wire
Mounti_J
Hole
(BACK VIEW)
18