The JAGUAR is a self-
contained condensate removal
system for use directly inside
the tubing chase of high-wall-
mount air conditioners.
Specifications
Power supply:
Power consumption: 16 W max., 0.25 W when idle
Alarm relay:
Capacity:
Maximum head:
Ambient temp:
Water temp:
Material:
Discharge tube:
Dimensions:
IP:
12
3
11
10
9
8
2
7
6
5
4
1
3
2
1
0
0
0
1
1
2
0
120/240 Vac, 50/60 Hz Auto sensing
5A, 30 Vdc, 250 Vac Break on fault
12 litres/hour max. (3.17 US gal/h)
Vertical >20 m (65 ft), Horizontal >100 m (328 ft)
Suction 1 m max. (3.28 ft)
0 - 40°C
25°C max.
Flame retardant ABS UL94 5VA
6 mm (1/4") ID
175 x 46 x 40 mm (6.9" x 1.8" x 1.6")