Leviton 6327-1 Manual De Instrucciones página 4

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4. Use the supplied anchors and screws for mounting on drywall or plaster; drill
two 3/16" (5mm) diameter holes at the marked locations; use a hammer to tap
the nylon anchors in flush to the wall surface and fasten sub base using the
supplied screws. Do not over tighten.
5. Connect the wires from your system to the thermostat terminals as shown in
the wiring diagrams. Carefully dress the wires so that any excess is pushed
back into the well cavity or junction box. Ensure that the wires are flush to the
plastic sub base. The access hole should be sealed or stuffed to prevent drafts
from the wall affecting the thermostat.
6. Before the thermostat is reinstalled on the sub base, install the optional clock/
timer, indoor remote sensor and outdoor remote sensor, if used. Refer to the
installation instructions supplied with each option. Also, check the position of
the slide switches on the lower left comer on the back of the thermostat (see
Figs. 1 & 2 ).
7. To replace the thermostat on the subbase, position the thermostat on the
hinged tabs located at the top of the sub base. Gently swing the thermostat
down and press on the bottom center edge until it snaps in place.
ON
OFF
OFF
4 Minutes
(min. ON/OFF)
Keyboard Unlocked
Fan Immediate
with Heat Call
(Figure 1)
LEVITON
6
Untitled-4
6-7
SWITCH #
ON
#1
2 Minutes
(min. ON/OFF)
#2
Keyboard Locked
#3
Fan ON with Plenum switch
OFF
Normal
Unused
4 Minutes
(min. ON/OFF)
Keyboard Unlocked
Economy
Unused
(Figure 2)
LED#1, Icon OFF
LED#2, Icon OFF
USING THE THERMOSTAT WITH LEVITON'S DECORA HOME CONTROL
The thermostat will work with Decora Home Controls Cat. Nos. 6337 (Universal Receiver
Module) or 6325 (Telephone Transponder Module). Cat. Nos. 6325 and 6337 have dry
contact relay terminals that can switch the thermostat's energy saving mode comfort
mode and back.
A. Using low voltage wire, connect CLK1 to one side of the dry contact on the
6325 or 6337 as shown on wiring diagram.
B. Using low voltage wire, connect CLK2 to the other side of the dry contact on
the 6325 or 6337 as shown on wiring diagram.
C. Set the Unit Code and House Code on the 6325 or 6337 and make certain that
the controlling DHC Transmitter Unit Code and House Code matches the
settings on the 6325 or 6337.
D. Plug your 6325 or 6337 to a receptacle.
E. Test your setup and make sure that Cat. Nos. 6325 or 6337 responds to the
commands coming from the DHC transmitter. If not, check the Unit and House
codes again and make sure the transmitter and the 6325 or 6337 matches.
Follow steps 1-7 listed in the installation instructions.
11/30/00, 3:11 PM
English
ON
OFF
SWITCH #
ON
#1
Add On
#2
UnUsed
#3
2 Minutes
(min. ON/OFF)
#4
Keyboard Locked
$5
Comfort
#6
Unused
#7
LED#1+ Filter Icon
#8
LED#2+ Wrench/Fault Icon
LEVITON
7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

6327-2

Tabla de contenido