Idiomas disponibles

 GAIN: Microphone input sensitivity
GAIN: +15 dB
GAIN: +12 dB
GAIN: +9 dB
GAIN: +6 dB
GAIN: +3 dB
Normal
GAIN: 0 dB
sensitivity
GAIN: -3 dB
GAIN: -6 dB
GAIN: -9 dB
GAIN: -12 dB
GAIN: -15 dB
 ATOFF: Automatic microphone off countdown under mute status
OFF
This function is deactivated.
1
1 minute countdown to turn off.
10
10 minute countdown to turn off.
30
30 minute countdown to turn off.
(Default 10 minute)
 RC: Remote set Configuration
Only frequency and group setting
rC-FrE
will be synchronized.
All data setting will be
rC-ALL
synchronized.
(Default rC-FrE)
VOLUME ADJUSTMENT
In non-setting mode, adjust the volume from 0 to -31 dB using the ▲/▼ buttons.
The minimum volume is -31 dB.
The maximum volume is 0 dB.
The default volume setting is -10 dB.
OTHERS
The transmitter's battery level is also shown on the LCD display. If the battery level is ≤ 2 V, the
frame around the battery level will flash and the backlight turns into red as a warning (for MI-
RD1CU16 and MI-RD2CU16).