Interlogix Transition Serie Manual Del Usuario página 2

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Testing the reader
1. Power up the reader. Verify the power-on self
test LED/beep sequence:
- green LED flashes; two short beeps
- yellow LED flashes; three short beeps
- red LED flashes
- yellow LED flashes
2. Verify the yellow LED lights indicating the
reader is ready.
3. Present a badge that has been properly
enrolled in the system. Verify the green LED
lights and a short beep is heard.
Removing the cover
To remove the cover, squeeze the sides of the top
cover and pull to release the cover.
Specifications
Colors
Black, Charcoal, Gray
Power supply
Linear DC recommended
Voltage range
5 - 16 VDC
Temperature
-31°F to 149°F (-35°C to 65°C)
a
range
Cable
200 ft. (60.96 m) max.
distance to
@ 22 awg 12 VDC
b
panel
300 ft. (91.44 m) max.
@ 20 awg 12 VDC
500 ft. (152.4 m) max.
@ 18 awg 12 VDC
c
Read Range
Proximity Perfect cards are not
(Distances
supported by the Transition Series
may vary
reader.
depending on
- CASI ProxLite: up to 3.5" (8.89 cm)
environment.)
- HID Proximity: up to 3.5" (8.89 cm)
Wiegand
- Proximity: 4002 (40-bit) 12 digits
d
output
- HID Proximity/Corporate
1000: Most formats (26 to 174-bit)
Regulatory
UL 294, CE, and FCC Part 15
approvals and
standards
UL evaluation for UL Listed Installations:
a. -25°F to 125°F (32°C to 52°C)
b. 500 ft. (152.4 m) max. @ 22 awg 12 VDC
200 ft. (60.96 m) max. @ 22 awg 5 VDC
c. Proximity: up to 3.0" (7.62 cm)
HID Proximity: up to 3.0" (7.62 cm)
d. HID Proximity/Corporate 1000: Most formats (up
to 64-bit)
The voltage specification for this reader is 5-16
VDC, although 12 VDC or greater is recommended
for better performance and cable run distances.
The recommended cable gauge is 18-gauge to 22-
gauge. Check with the cable supplier to determine
the best choice for the application and installation
distance.
FCC compliance
The FCC requires the following statement: This
reader uses radio frequency energy, has been
tested, and complies with the limits of FCC testing.
Changes, modifications, or disregard of proper
installation and instructions not expressly approved
by UTC Fire & Security are strictly prohibited by the
FCC and could void the user's authority to operate
the equipment.
Ordering information
Product
T-100
(3 covers, 18" / 45.7 cm pigtail wire)
T-100
(3 covers, 84" / 214 cm pigtail wire)
Note: Each part number includes all three colors of the
cover plates (black, charcoal, gray).
Copyright © 2011, UTC Fire & Security.
All rights reserved.
The Transition Series product name and logo are
trademarks of UTC Fire & Security. Other trade names
used in this document may be trademarks or registered
trademarks of the manufacturers or vendors of the
respective products.
Document number: 460949002B - November 2011
Part numbers
TP-RDR-100a
TP-RDR-100b

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Transition t-100Tp-rdr-100aTp-rdr-100b

Tabla de contenido