CUSTOMER RESPONSIBILITIES TABLE
MAINTENANCE TASK
ENGINE
check oil level
change oil
check air filter
clean/replace spark plug
PRESSURE WASHER
check/clean inlet screen
check high pressure hose
check soap and chemical
hose and filter
check gun and wand for leaks
prepare for storage
ENGINE
To Check Oil
1.
Shut down engine and place on a
level surface.
2.
Remove filler cap/dipstick and
wipe it clean.
Filler cap/dipstick
3.
Insert and remove the filler
cap/dipstick without screwing it
into the filler neck. Check the oil
level shown on the dipstick.
Every 25
Before
hours or
each use
yearly
X
X
X
X
X
X
Prepare unit for storage if it is to remain idle for longer
than 30 days
4.
If the oil level is low, fill to the
edge of the oil filler hole with the
SAE 10W-30 oil.
NOTE: Other viscosities shown in the
chart may be used when the average
temperature in your area is within the
recommended range.

SAE Viscosity Grades

Synthetic 5W-30, 10W-30
F -20
C -30
STARTING TEMPERATURES RANGE
ANTICIPATED BEFORE NEXT OIL CHANGE
15- ENG
Every 50
hours or
yearly
X
Oil Filler
Cap/Dipstick
Upper Limit
Lower Limit
**
*
0
20
32
40
60
-20
-10
0
10
Every 100
hours or
yearly
X
80
100
20
30
40
D25852