Features
1. Test Button: Turns on the test instrument.
2. ON LED: Illuminates when Test Button
is pressed; indicates the tester is ON
3. CORRECT LED: Indicates that the motor
connections correspond to the direction
of motor rotation
4. INCORRECT LED: Indicates that the
motor connections do not correspond
to the direction of motor rotation
4
3
2
1
Motor Rotation Operation
1. Press the Test Button. If the green ON
LED does not illuminate, replace the
battery.
2. Plug the test leads into the corre-
sponding jacks of the test instrument.
Do not connect the motor rotation leads
to a source of voltage or current.
Damage to the test instrument can result.
3. Connect the three test leads of the test
instrument to the terminals or leads of
the motor.
6
Greenlee Textron / Subsidiary of Textron Inc.
Motor Rotation Indicator