4. CLEANING AND MAINTENANCE

4.1 Cleaning
The system must be turned off and the plug must be removed from the socket before the electric
hydraulic pump may be cleaned.
The electric hydraulic pump may be cleaned with a damp cloth. A mild detergent solution is permitted for
removing oil or stubborn dirt. Do not use corrosive agents as they can damage the hydraulic
connections.
Fit the rubber protective cover to prevent dust when quick couplings are not used.
Prevent all possible contamination of the system.
4.2 Maintenance
Maintenance must be performed by qualified and certified personnel at all times!
The electric hydraulic pump must be turned off and the plug must be removed from the socket before
maintenance may be performed.

4.2.1 Hydraulic oil

1. Check the hydraulic oil level when all cylinders are retracted every 40 hours. Top up if needed (Section
3.3). The system must be checked for leaks if large quantities of oil must be regularly added.
2. Check the cleanliness of the hydraulic oil every 120 hours. The oil must be replaced if it becomes dirty.
Ensure that all cylinders are in the retracted position, tap off the oil and fill the reservoir again with
hydraulic oil (Section 3.3).
3. Replace the hydraulic oil every 400 hours. Ensure that all cylinders are in the retracted position, tap off
the oil and fill the reservoir again with hydraulic oil (Section 3.3).
4.2.2 System
The nature and frequency of the system check must be determined by the person responsible for the
installation. The following points serve as a guideline.
1. Regularly check the system for leaks.
2. Regularly check the cylinders if cylinders are used. Nature and frequency according to the user
instructions for the cylinders.
3. Regularly check whether any fittings are bent or damaged. Damaged hydraulic fittings must be
immediately replaced to prevent accidents.
4. If hoses are used, check them regularly. Nature and frequency according to the user instructions for the
hoses.

5. TECHNICAL DATA

5.1 Conversion kits
Article number overview:
EP13S / 18S / 13D / 18D
EP18SS
EP18DS
EP211S / EP211D
EP211SS
EP211DS
Bega International BV – Assembly Manual Betex® EP13, EP18 & EP211 series – Oct. 2015
From 120V to 230V
830 0096
830 0097
830 0098
830 0099
830 0100
830 0101
8
From 230V to 120V
830 0090
830 0091
830 0092
830 0093
830 0094
830 0095
6