Dosper evo
7.5 Duplication
Place your duplicating flask under the
mixing tip and press the activation but-
ton (7). The two LEDs (8) behind the
mixing head will light up. On the one
hand this is to control the operation of
the pump, on the other hand the view
in the work area is improved. As long
as the silicone in the mixing tip is not
cured, an arbitrary number of flasks can
be filled one after the other. Leave the
tip on the mixing head after the filling
process, it will serve as a closure of the
7.6 Bottle-/canister change
Release the quick couplings from the
machine by pressing the locking button
and pulling upwards.
Screw the quick couplings to the new
bottle/canister as described above.
30
30
mixing head. Next time the machine is
going to be used just remove the old
mixing tip by an anti-clockwise turn of
90° and replace it by a new one.
Important: Never activate the machine
when a mixing tip with cured material is
still locked to the mixing head!
In case the Dosper evo is not used for a
longer period of time we recommend to
turn the machine off at the main switch
(1).
Important: Never swap the connec-
tion sides of the bottles/canisters (see
chapter 8.1).