Grounding Instructions; Specifications - Textron Greenlee 555DX-22 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Grounding Instructions

Electric shock hazard:
• Do not modify the plug provided
with the tool.
• Connect this tool to a grounded
receptacle on a 15 amp ground
fault protected circuit.
Failure to observe these warnings
could result in severe injury or death.
This tool must be grounded. In the event of a malfunc-
tion or breakdown, an electrical ground provides a path
of least resistance for the electric current. This path of
least resistance is intended to reduce the risk of electric
shock.
This tool's electric cord has a grounding conductor and
a grounding plug as shown. Do not modify the plug.
Connect the plug to a corresponding GFCI-protected
receptacle that is properly installed and grounded
in accordance with all national and local codes and
ordinances.
Do not use an adapter.

Specifications

Height .................................................................................................. 100.1 cm (39.4")
Width ........................................................................................................ 68 cm (26.8")
Depth ..................................................................................................... 58.4 cm (23.0")
Mass/Weight (bender without shoes or roller supports ..........................124 kg (273 lb)
Power Supply .................................................................................... 220 VAC, 15 amp
Operating Conditions
Temperature .......................................................... –20 °C to 49 °C (–5 °F to 120 °F)
Relative Humidity .................................................................................... 0% to 98%
Capacity .............................................................. 1/2" to 2" conduit, schedule 40 pipe
Greenlee / A Textron Company
555DX-22 Electric Bender
Plug
Do not modify the plug provided. If it will not fit the
outlet, have the proper outlet installed by a qualified
electrician. Improper connection of the equipment-
grounding conductor can result in a risk of electric
shock. The conductor with insulation having an outer
surface that is green with or without yellow stripes
is the equipment-grounding conductor. If repair or
replacement of the electric cord or plug is necessary,
do not connect the equipment-grounding conductor
to a live terminal. Check with a qualified electrician or
service personnel if the grounding instructions are not
completely understood, or if in doubt as to whether the
tool is properly grounded.
GFCI-protected receptacle
6
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
NEMA 6-15
Receptacle

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Greenlee 555 serie

Tabla de contenido