1. Place single mount leg up on the side of the tray.
2. Set the proper distance of the opposing leg to
match the tray width by disengaging the pin (1) from
the leg weldment (2) and the cross bar.
Greenlee / A Textron Company
3. Draw out the strap from the ratcheting mechanism
4. Ratchet the strap to secure the mount to the tray.
2
5. Mount the feeder according to which direction the
1
6. To remove the feeder from the cable tray, pull the
6
and hook to the opposing leg hook.
Be sure it is tight enough to hold the mount. Do
not overtighten as this may damage the ratcheting
mechanism or the tray.
cable is to be fed by disengaging the pull pin and
setting the feeder on the cross bar. Slide the feeder
along the cross bar to the desired position to feed
cable. Be sure that the pull pin properly engages
into a hole on the cross bar.
detent pin and lift the feeder off of the mount cross
bar. Pinch and pull down the ratchet strap's release
mechanism. Use caution when releasing the hook
from its mount, as the auto-retractable strap may
cause injury if let go with personnel in the vicinity.