Start input function
This menu allows selecting input operation modes (see paragraph
"Activation inputs"):
no:
Start inputs from terminal board are disabled. Radio inputs
operate in StAn mode.
StAn:
Start and Pedestrian Start input standard operation,
according to menu setups.
AP.CH: Start impulse always controls the opening phase, Pedestrian
Start always controls the closing phase.
PrES:
Manned operation; the gate will open as long as the Start
input stays closed and it will close as long as Pedestrian
Start stays closed.
oroL:
Timer-operation; the gate stays open while the Start input or
Pedestrian Start input is closed; as soon as the contact
opens, the pause count down will start.
Brake Function
This menu allows to activate the brake function, so that your gate
stops immediately because of command or safety intervention avoi-
ding a further movement. This inconvenience happens when a sliding
motor provided with single-plate clutch is installed on a very heavy
gate: owing to inertia, the gate does not stop immediately and it can
move about ten centimetres, reducing safety.
no
brake function is not activated
Si
brake function is activated

Stop Input

This menu permits to select the functions associated to the
command of STOP .
no
the input STOP is not available
ProS
the input STOP stops the gate: pressing the command START
the gate continues the motion
invE
the command STOP stops the gate: at the next START the
gate starts moving in the opposite direction.
NOTE: during the pause, the STOP command will stop the pause time
count, the next START command will always close the gate.
Photocell 1 input
This menu allows enabling the input for type 1 photocells, that is to
say, photocells active both during the opening and closing phase (see
paragraph "Installation").
no:
input disabled (ignored by the control unit).
No jumper with the common is required.
AP.CH: input enabled.