Option Relay Output; Courtesy Light; Lock; Service Reporting - V2 SPA HYPERFOR-I Manual Del Usario

Motor electromecanico irreversibles 230v trifasico con inverter para puertas correderas hasta 4000 kg de peso
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

20 - OPTION RELAY OUTPUT

The unit has three relay outputs with normally open dry contact
that can be configured with different functions through the
parameters
,
and
REL1
REL2
In this table are the available functions and the value to set for the
parameters
,
and
REL1
REL2
FUNCTION
REL1 REL2 REL3

Lock

Opening command

Closing command

Service reporting

Safety devices test
Custom

Courtesy light

Indication of movement
Connect the device controlled by the REL1 output to terminals
Z4 and Z3
Connect the device controlled by the REL2 output to terminals
Z6 and Z5
Connect the device controlled by the REL3 output to terminals
B2 and B1
m
The relay outputs act as simple switches and do not
provide any power supply.
The power supply to the device Vsupply can be provided by
the unit or the line.
If you use the power supply of accessories, 24 Vac or
12 Vdc, make sure that the current required is compatible
with that supplied by the unit.
B2
B1
REL3
V
SUPPLY
a
parameter
DEFAULT =
REL1
a
parameter
DEFAULT =
REL2
a
parameter
DEFAULT =
REL3
REL3
REL3
VALUE
SERR
APRE
CHIU
SERV
TEST
CUST
LUCI
MO.NO
MO.NC
Z6
Z5
Z4
REL2
V
SUPPLY
REL1
V
SUPPLY
(courtesy light)
LUCI
(no function)
NO
(no function)
NO
20.1 - COURTESY LIGHT
The courtesy lights can be operated in the following ways:
1. Timer control
The lights turn on when the opening is commanded and stay
on for the time set.
Select the value
desired time.
2. Moving + timer
The lights turn on when the opening is commanded; when the
gate stops (open or closed) the lights stay on for the time set.
Select the value
desired time.
3. Timer by AUX control
The lights are activated by a remote control stored on channel
4 of the MR receiver and stay on for the time set.
Select the value
desired time.
4. Light monostable
The lights are activated by a remote control stored on channel
4 on the receiver MR and stay on for the whole duration of the
command transmission.
Select the value
5. Light bistable
The lights are activated by a remote control stored on channel
4 of the receiver MR: a first command turns on the lights, a
second command turns them off.
Select the value
6. Bistable + timeout
The lights are activated by a remote control stored on channel
4 of the MR receiver and stay on for the time set.
A second transmission before time runs out turns off the lights.
Select the value
desired time.
20.2 - LOCK
The relay is closed for three seconds each time a new opening
manoeuvre is started.
To facilitate the release of the lock you can set a time for the
water hammer: before you start opening the gate is controlled to
Z3
Z2
Z1
close for a short time.
To activate this function, set the backlash time through the
20.3 - SERVICE REPORTING
The relay is activated when the cycle count set for the Service
request reaches
0
activate a warning light.
20.4 – OPENING COMMAND
The relay is activated when the motor is controlled when opening:
in this way it is possible to activate secondary motors or send
synchronized signals with the movement of the main motor.
- 52 -
in the parameter
T.LUC
LUCI
in the parameter
CICL
LUCI
in the parameter
and set the
TIM
AUX
in the parameter
MONO
AUX
in the parameter
BIST
AUX
in the parameter
TOUT
AUX
(Chapter 22.4): in this way it is possible to
and set the
and set the
and set the
T.AR

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hyperfor 4000-i-m4

Tabla de contenido