DIP
Modes and functions
DIP1
DIP2
Advance warning
DIP3
Opening mode
Automatic or step-by-step mode
DIP4
(for pedestrian and total operation)
Automatic mode optional
DIP5
(only if DIP4 = ON)
DIP6
Opening photocell testing
DIP7
Reserved for future upgrades
DIP8
Reserved for future upgrades
DIP9
Closing photocell testing
DIP10 Reserved for future upgrades
T.LG: garage light time
If the garage lighting circuit has been connected to the
control panel, regulate the time which the lights shall
remain on using T.LG.
• Minimum value: 3 seconds; maximum value: 90
seconds
14
KM1800: function and mode selection using SW2 (DIP1 = OFF)
KM1800: potentiometer adjustment
Option
Effect
OFF
the flashing light comes on and the operation begins after a 3
ON
second warning
the flashing light comes on and the operation begins
OFF
immediately
step-by-step opening (the gate halts if a key command is
ON
activated during opening, and closes if activated again)
collective opening (the control board does not obey the key
OFF
commands during opening)
automatic mode (the gate closes automatically after the
ON
standby time has passed, which is adjusted using T.E.)
step-by-step mode (the gate only closes when receiving the key
OFF
command)
during standby, the gate obeys the key commands (this can be
ON
closed before standby time finishes)
the gate cannot be closed until standby time finishes; a key
OFF
command (or photocell activation) will cause standby time to
restart
ON
testing enabled
OFF
testing disabled
ON
always place in OFF
OFF
always place in OFF
ON
always place in OFF
OFF
always place in OFF
ON
testing enabled
OFF
testing disabled
ON
always place in OFF
OFF
always place in OFF
T.E: gate open standby time
If automatic functioning mode has been programmed
(DIP4=ON), set T.E. to adjust standby time with the gate
open (before automatic closing begins).
• Minimum value: 0 seconds; maximum value: 90
seconds
P.M: motor torque
Adjust P.M at its maximum value, since the operator has a
mechanical clutch for torque adjustment.