Input Power; Work Clamp, Ground Cable; Automatic Purge System; Checking Air Quality - Forney 700P Manual De Instrucciones

Cortadora de plasma
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Input Power

Check the power source for proper input voltage.
Make sure the power source meets circuit protection and wiring requirements.
Plug unit in and close main disconnect switch to supply primary power to the system.

Work Clamp, Ground Cable

Check for a solid ground cable connection to the work piece.

Automatic Purge System

Once you have connected your compressed air supply, power on the machine. The cooling
fan will start and an 8 second automatic gas purge is activated (pre-flow) to remove any
condensation that may have accumulated in the torch and cable while the system was shut
down.
When the gas purge is complete, the pilot arc can be initiated by pressing the torch trigger
and cutting can begin. When you have finsihed cutting, there will be an automatic post-flow
of compressed air for 20 seconds to cool the torch.

Checking Air Quality

To check air quality, deactivate the torch (post-flow) and place welding filter lens in front of
the torch. Any oil or moisture in the air will be visible on the lens.
DO NOT initiate pilot arc while checking air quality.

Operation

Description

The Forney 700P plasma system is a highly portable, generator-friendly plasma cutting system
appropriate for a wide-range of cutting applications.
The Forney 700P plasma system includes: two complete sets of consumables needed for either
maximum performance or maximum versatility (Shield Cup, Air Diffuser Ring, Electrode and Nozzle),
torch assembly, torch lead, ground cable with ground clamp, and plasma inverter power source.
Additional consumables and accessories can be ordered from any Forney Authorized Dealer. See
Maintenance and Parts section of this manual for additional information.
Weight: 35 Lbs. (15.88Kg)
Power Source Rating & Specifications
Refer to the rating plate on the back of the machine for ratings and specifications.
Generator Requirements:
Engine Drive
Output Current
Performance
3,000 - 11,500 W
20 - 50 A
Full Arc Stretch
WWW.FORNEYIND.COM
17

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido