Descargar Imprimir esta página

Sammic TM-5 Instrucciones De Uso página 3

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
OPERATION GUIDE
1. Turn-on the lock catch to "open" shown on
the panel, and remove the milk tank. Clean
the milk and water tanks before using the
appliance.
2. Fill the water tank with water.
3. Put the milk tank back into the internal water
tank, and turn it to "close" shown on the
panel.
During these operations, a little water in the
internal water tank will leak into the milk tank.
Let all this water out using the milk tap befo-
re filling the milk tank with milk. Since there is
an "O"-ring around the connector of the milk
tank for preventing leakage, no more water
will flow into the milk tank from the internal
water tank after this water is out.
Put the milk tank back and lock it quickly in
order not to let more water leak into the tank.
4. Fill the milk tank with milk and fix the lid.
5. Turn on the machine. Start the switch on "1".
The indicator lights up and the machine starts
working. When the temperature reaches 60-
65ºC the power automatically cut off. When
the temperature drops to 50-55ºC, the power
will automatically turn on. The machine is
thermostatically controlled to keep the milk
temperature between 55-65ºC.
6. Put the cup on the splash tray and get the
milk using the milk valve.
7. Make sure the switch is at "0" and unplug the
machine if it will not be used for a long time.
WARNINGS
1. Refer to these instructions before using this
machine. This machine must be connected
with the suitable power supply and the earth
wire.
2. Place the machine on a flat, stable surface in
a well ventilated area. Avoid placing your
machine near inflammable products and
explosives.
3. Caution: the internal tank must be filled with
water before turning the machine on. The
water level must be 5cm above the heater. If
the machine is used for a long time, water
must be added.
4. The milk tank must be settled and locked as
the symbols show on the panel. Otherwise,
the tank will not be well fitted and the water
will leak into the milk tank.
5. Make sure all the milk in the tank has flowed
out before cleaning and moving the tank.
Otherwise, the residual milk will leak into the
water tank as the milk tank is removed.
6. To protect the unit and prevent injuries, be
careful not to soak the barrel. You may clean
it using a cotton cloth soaked in detergent
and water, and wipe it over with a clean cloth.
7. To prevent injuries, the damaged power cord
should be replaced by the manufactured or
by an authorized service engineer.
8. A few accessories can be replaced directly by
the user. If there is something wrong with
them, please contact the manufacturer
and/or an authorized service engineer.
9. This appliance is designed for commercial
use and is for indoor-use only.
10. The appliance will be thermopositive then
working, specially the metal shell. Keep chil-
dren and elder back, and be careful not to
touch the shell when working.
11. Set the switch back at "0", cut the power off,
make sure no more milk remains, and clean
the tank and the defrosting tray. Do these
after using the machine every time.
12. This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or
lack of experience and knowledge, unless
SPECIFICATIONS
C
(litres)
APACITY
E
LECTRICAL SUPPLY
L
OADING
D
IMENSIONS
- Width
- Depth
- Height
N
ET WEIGHT
they have been given supervision or ins-
truction concerning use of the appliance by
a person responsible for their safety.
Children should be supervised to ensure
that they do not play with the appliance.
13. If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualified persons in order
to avoid a hazard.
14. CAUTION: In order to avoid a hazard due to
inadvertent resetting of the thermal cutout,
this appliance must not be supplied through
an external switching device, such as a
timer, or connected to a circuit that is regu-
larly switched on and off by the utility.
TM-5
TM-10
5
10
230 V / 50Hz / 1~
1000 W
1500 W
240 mm
310 mm
270 mm
340 mm
510 mm
510 mm
8.5 Kg
12 Kg
3