Descargar Imprimir esta página

Stagnoli H230 Manual Del Usaurio página 23

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

GB
00
cancella
reset parametri
cancella 1 radiocomando
cancel l a tutta memori a radi o
ttca
= automatic closing time
t m1
= motor working time
aped
= pedestrian opening
rlap
= slowed stroke in opening
rlch
= slowed stroke in closing
senc
= encoder sensitivity
fm1a
= motor power in opening
fm1c
= motor power in closing
brak
= braking current
trel
= N.O. output activation time
tdec
= deceleration time
da
= opening direction
ca
= automatic closing
ba
= blocks impulses during opening
bp
= blocks impulses during pause
cr
= rapid closing
2p
= open/close operation
pl
= prefl ashing
sv
= suction lock
re
= energy saving
fcm
= magnetic limit stop
en
= encoder operation
ss
= soft start
oc
= open/close operation
it
= itotal inversion after meeting an obstacle
2b
= two safety ribs
cf
= operation of the fi xed code receiver
al
= alarm
reset parametri
cancella 1 radiocomando
cancella tutta memoria radio
apprendimento
leggi codice
23
00
= instant power absorbed by the motor
WARNING: For the navigation diagram of the English menu,
see the instructions in the other languages.
= setting of factory parameters
= cancels one transmitter
= learning the stroke
= to identify and recognise transmitters
lingua
italiano
english
= cancel all registered transmitters
apprendimento
leggi codice

Publicidad

loading

Productos relacionados para Stagnoli H230