Technical Specifications - Panduit PPTS Manual De Operación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

© Panduit Corp. 2016
OPERATION
1. Reading the selector knob from the bottom of the tool, flip the
knob to select the cross section of cable ties to be installed:
MIN:
Approx. 0.098" (2,5 mm) wide cable ties
INT:
Approx. 0.142" (3,6 mm) wide cable ties
STD:
Approx. 0.190" (4,8 mm) wide cable ties
If necessary, further adjust tension per Tension Adjustment
instructions below.
2. Loop cable tie around bundle and insert the tip through the
head. Pull the tie up snug on the bundle by hand.
3. Insert the strap of the cable tie into the side of the tool. With
the nose of the tool flush to the cable tie head, squeeze the trig-
ger to tighten the cable tie. Typically, only one depression of
trigger is necessary for cable tie cut-off.
TENSION ADJUSTMENT
There is a tension indicator on the handle of the tool. The tension
setting can be adjusted by turning the selector knob:
1-3 for MIN, 3-5 for INT; and 6-8 for STD.
DAILY TOOL INSPECTION
1. Visually inspect nose area for foreign matter and cable tie scrap. Keep this area clear of foreign matter.
2. Visually inspect applied cable ties for correct tension and cut-off to verify the working condition of the blade and gripper.
TECHNICAL SPECIFICATIONS - Air Supply
Recommended regulated air pressure supplied to tool
(pressures other than recommended may result in
unsatisfactory operation):
Air consumption at 30 cycles per minute:
Line pressure supplied to regulator:
Filter/regulator requirements:
Lubrication for air supply:
Recommended filter/regulator unit (supplied by user) with
1/8" NPT ports and 1/4" quick disconnect (industrial
interchange) plug:
Recommended main air supply hose (10 ft.) from
filter/regulator to tool (supplied by user); includes a 1/8" NPT
male connector (to regulator) and a 1/8" quick disconnect
socket (to tool):
PNEUMATIC TOOL OPERATION MANUAL
ITEM
Regulator settings: 75 PSIG (5,2 bar) with a max. 10 PSI
.091 cfm @ 75 PSIG (0,043 l/sec @ 5,2 bar)
Minimum 70 PSIG (4,8 bar), Maximum 85 PSIG (5,8 bar)
5 micron maximum element rating, 5 PSI (0,3 bar)
maximum pressure drop @ 70 PSIG (4,8 bar) inlet pressure
and 12 cfm (5,7 l/sec) flow minimum.
Air line lubricators are NOT to be used.
Recommended source: Panduit Part Number: PL289N1
Recommended source: Panduit Part Number: PPH10
Page: 3 of 20
DESCRIPTION
(0,7 bar) drop. DO NOT EXCEED 90
PSIG (6,2 bar).
EU Panduit Part Number:MK-06
EU Panduit Part Number:
PPH10G
PPTS-EN

Publicidad

Tabla de contenido
loading