Textron Tempo PE961 Manual De Instrucciones página 6

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Specifications
Monitor Impedance .......................................................................................... > 400 kΩ @ 1 kHz
Loop Resistance (maximum) ................................................................................................ 5 kΩ
Current Draw .................................................................................................................... < 15 mA
DC Resistance
Talk Mode ................................................................................................................... < 300 Ω
Idle ............................................................................................ > 10 MΩ (30 µA @ 300 VDC)
Monitor ...................................................................................... > 10 MΩ (30 µA @ 300 VDC)
Temperature
Operating .................................................................................... –34 to 60 °C (–29 to 140 °F)
Storage ....................................................................................... –50 to 75 °C (–58 to 167 °F)
Battery ........................................................................... 9 V alkaline (NEDA 1604A or IEC 6LR61)
Introduction
The PE961 Telephone Test Set is an advanced, convenient, and easy-to-use telephone line
troubleshooting device. Equipped with a number of LEDs and alarms, it lets the user know the
operating mode and provides alerts for hazardous situations.
LEDs:
Polarity
Low Battery
Talk/Monitor
Tones: Low Pitch
Middle Pitch
High Pitch
The LEDs and tones indicate various conditions and functions. They are shown throughout the
manual in italic type.
The PE961 produces two types of alarms to alert the user to potentially hazardous situations.
• Excessive DC voltage is indicated by three low-pitched tones in a row.
• AC line voltage is indicated by continuous ringing.
If you hear either of these alarms, which are repeated in bold italic type in this manual, remove
the test set from the line carefully and immediately.