Check if all i-Micro inverter GT260 are properly installed and verify the AC solar switch is in "ON"
1
position in AC load center, and then check that LED indicator on i-Micro inverters shows solid
green LED.
Install an electrical outlet (fixed or floating) on the AC solar switch, and place the i-Manager
2
so that its AC cord can reach this dedicated outlet directly without any extended line to avoid
possible electrical interference. Please refer to the pictures for Typical Single Phase System
Connection Design and Typical Three Phase System Connection Design in the following page.
3
Use Ethernet cable to connect i-Manager to Ethernet router.
4
(Option): In cases where the internet router is located far away from i-Manager, i-Energy provides
i-Bridge accessory which can bridge connection between i-Manager and router by power line
communication to avoid long internet cabling distance. Or alternatively, Powerline Ethernet
Bridges available in electrical retail stores can be used to connect i-Manager to the Ethernet
router without the long Ethernet cabling.
4
ROW diagram
220V, 50-60Hz