Troubleshooting
Problem
Unit does not run.
Unit runs poorly.
Piston does not go through conduit.
Greenlee / A Textron Company
Li'l Fisher
Probable Cause
Switch damaged or worn out.
Motor damaged or worn out.
Filter dirty.
Tank full.
Wrong size piston.
Conduit run obstructed.
EMT couplings loose.
8
390 Power Fishing System
®
Probable Remedy
Replace switch.
Replace motor.
Clean and dry the filter.
Empty tank.
Select correct size piston.
Clear the conduit run. Check for
flattened bends.
Tighten couplings.
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070