Pujol Winner DC Instrucciones De Instalación Y Reglaje página 13

Accionador central de puertas enrollables
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Failure
Possible cause
Programming cannot
Open door
be accessed
Faulty connections
Lack of power supply
Unlocked engine
The door does not
Blown line fuse.
open or close
Accessories have short circuit
Wrong connection of the unloc-
king device
The door does not
Verification of the sense of rotation
open
The door does not
The photocell is activated or
close
damaged
Verification of the sense of rotation
The door moves
The actuator has been unlocked
slowly
or the power supply has been
interrupted.
The door opens when
Some of the accessories connected
connected to 220 V.
to the terminals 3-5, 6-5 or 7-8 on
closed position.
Adjust the level of power
The door changes
the sense of its
movement.
The door stops after
Faulty Hall Sensor
moving about 18 cm
and the sense of the
movement does not
change
Photocell and
Wrong position of the rotation #3
automatic closing
dip-switch
features of the door
are inverted
The door does not
Wrong programming
close smoothly or au-
tomatically
Note: If the door does not work after verifying the above described solutions, it is advisable to replace the electronic equipment or
contact our technical department.
winner DC
roubleshooting
Solution
Move the shutter to any position and access to programming.
Switch off the supply for 10 seconds and program again
Check to ensure the connections are according to the diagram (Image 6)
Check the terminals 15 and 16 or 26 and 27 to detect if they have 220 V.
Lock the engine to activate the safety device. Check that the D light is on.
Replace the 1 A fuse.
Disconnect all the terminals of the accessories 8 (-) and 9 (+) (there should
be a DC voltage of about 30 V) and connect them again individually.
Connect the device properly according to the diagram (Image 6(A))
Press the terminals 5 and 6 with the door half opened and the door should
open.
Verify the power supply of the photocell, its connection and the existence of
obstacles. If there is no photocell, bridge the terminals 4 and 5.
Press the terminals 5 and 7 with the door half opened and the door should
close.
The first opening movement will be at a slow speed until the door reaches
the bumpers.
Connect the accessory to an opened position (pusher, receiver...).
Adjust with the potentiometer. Turn the potentiometer clockwise to increase
the power and counter clockwise to reduce it.Check that that the shutter
is properly compensated by the springs. With the engine unlocked, check
manually that the door moves freely.
Remplacer le Senseur Hall en respectant les couleurs et les bornes.* Lire
remarque annexe pour le remplacement du senseur.
Disconnect the power supply and change the position of the #3 dip-switch.
Follow the programming instructions of the device for the stroke and au-
tomatic closing of the door, as described in the installation and adjustment
instructions delivered with Winner DC. Programming should be made with
the door closed.
automatismos pujol
13
english

Publicidad

Tabla de contenido
loading

Tabla de contenido