CP 0315
F.
At each inspection, clean open bearings and
fill ¼ of the bearings open space with a good
grade ball bearing grease.
Troubleshooting
If the pneumatic machine does not start, has low
power or uneven performance, check the following
points.
♦
Check that the insertion tool being used has the
correct shank dimension.
Check that the pneumatic machine is getting the
♦
correct amount of lubricant. Too much lubrication
can cause starting problems, low power or
uneven performance.
Check that the compressed air system supplies
♦
the machine with sufficient air pressure to give
full power.
Check that the dimension and length of the air
♦
hose are according to the recommendations. See
"Installation".
If there is a risk of freezing, check that the
♦
machine's exhaust ports are not blocked.
If the machine function is still not satisfactory after
♦
this procedure, contact an authorised service
workshop.
Storage
>
Clean the machine properly before storage, in
order to avoid hazard substances. See "Dust and
fume hazard"
>
Pour approximately
1
⁄
2
the air inlet nipple, connect the machine to the
compressed air supply and start it for a few
seconds.
>
Always store the machine in a dry place.
Disposal
A used machine must be treated and disposed of in
such a way that the greatest possible portion of the
material can be recycled and any negative influence
on the environment is kept as low as possible, and
in respect to local restrictions.
9800 0554 90a | Original instructions
www.CrowderSupply.com • Toll Free: 888-883-5144
oz (5 cl) of oil directly into
Safety and operating instructions