Technical data HM6050-2
Frequency range:
Network inductance:
Max. current:
Voltage:
Artificial Hand:
PE simulating
network:
Connections
On front panel:
Artificial Hand:
Ground:
DUT:
Test Receiver
(test signal output):
On back panel:
AC power:
Ground:
EIA-232 interface:
Dimensions:
Weight:
Transient Limiter
Frequency range:
Transmission loss:
Max. input voltage:
Standing wave ratio (SWR): 1,5:1 or better
Other:
Ambient temperature:
AC power requirements:
Safety:
Color:
Subject to change without notice
9kHz...30MHz
Z=50Ω II(50µH + 5Ω)
error < 20% acc. to VDE 0876T1
2 x 16A continuous
230V AC, 50/60 Hz (factory setting)
220pF + 511Ω
50Ω II 50µH
banana jack 4mm
("Artificial Hand")
banana jack 4mm
Female AC supply voltage output with PE
50Ω BNC jack
("Test Receiver")
Power line cable, 3 x 1,5mm
male with PE
Aluminum block with thread, 4mm
40mm x 20mm x 20 mm
Sub-D. 9-pin, female
285mm x 125mm x 380mm (WxHxD)
6kg
150kHz - 30MHz
f= 150kHz - 30MHz
a=10dB + 1,5/ -0,5dB
f <1kHz — a>90dB
f >100MHz — a>50dB
at P=2W (average) ^ = +33dBm
U= ±50V DC
10°C ... 40°C
230V / 115V, 50-60Hz
Class I (IEC 1010-01/VDE 0411)