· SERVICE FLOW RATE = 9.3 GPM (35.2 LPM)
· DRAIN FLOW RATE: 1.5 GPM (5.7 LPM)
· PSI DROP @ FLOW RATE: 15.0 psi (1.1
kgf/cm 2 )
· OPERATING PSI OF SUPPLY: 20 psi - 120 psi
(1.47 - 8.45 kgf/cm 2 )
· OPERATING TEMPERATURE: 40° F - 100° F
(4.4° C - 38° C)
· ELECTRICAL: 24 VAC, 50/60 Hz (COMPUTER)
· SALT PER REGENERATION: VARIABLE
· EFFICIENCY: 4,400 GRAINS/LBS. SALT @ 2.25
LBS. DOSAGE
LIST OF CONTAMINANTS REDUCED
CONTAMINANT
BARIUM*
RADIUM 226/228*
NSF/ANSI STANDARD 44 TEST CONDITIONS: 35 ± 5 psi, 65 ± 10°F, pH 7.5 ± 0.5 at service flow rate
*HARDNESS WAS USED AS A SURROGATE FOR BARIUM AND RADIUM REDUCTION CLAIMS PER NSF/ANSI
STANDARD 44.
SOFTENING PERFORMANCE TEST
CHALLENGE
AVERAGE INFLUENT LEVEL
HARDNESS
NSF/ANSI STANDARD 44 TEST CONDITIONS: 35 ± 5 psi, 65 ± 10°F, pH 7.5 ± 0.5 at service flow rate
ADDITIONAL NOTES
• THE LIST OF SUBSTANCES WHICH THIS TREATMENT DEVICE REDUCES DOES NOT NECESSARILY MEAN THAT THESE
SUBSTANCES ARE PRESENT IN YOUR WATER SUPPLY.
• ACTUAL RESULTS MAY VARY DUE TO LOCAL WATER CONDITIONS.
• AN EFFICIENCY RATED WATER SOFTENER IS A DEMAND INITIATED REGENERATION SOFTENER, WHICH ALSO
COMPLIES WITH SPECIFIC PERFORMANCE SPECIFICATIONS INTENDED TO MINIMIZE THE AMOUNT OF REGEN-
ERATE BRINE AND WATER USED IN ITS OPERATION AND WILL ACHIEVE A RATING OF NOT LESS THAN 3,350
GRAINS OF TOTAL HARDNESS EXCHANGE PER POUND OF SODIUM CHLORIDE SALT AND SHALL NOT DELIVER MORE
SALT THAN ITS LISTED RATING. THE EFFICIENCY IS MEASURED BY A LABORATORY TEST DESCRIBED IN NSF/ANSI
44. THE TEST REPRESENTS THE MAXIMUM POSSIBLE EFFICIENCY THAT THE SYSTEM CAN ACHIEVE. OPERATIONAL
EFFICIENCY IS THE ACTUAL EFFICIENCY ACHIEVED AFTER THE SYSTEM HAS BEEN INSTALLED AND IS TYPICALLY
LESS THAN THE TESTED EFFICIENCY DUE TO INDIVIDUAL APPLICATION FACTORS INCLUDING WATER HARDNESS,
WATER USAGE, AND OTHER CONTAMINANTS THAT REDUCE THE SOFTENERS CAPACITY.
• A WATER SOFTENER IS NOT INTENDED TO BE USED FOR TREATING WATER THAT IS MICROBIOLOGICALLY UNSAFE
OR OF UNKNOWN QUALITY WITHOUT ADEQUATE DISINFECTION BEFORE AND AFTER THE SYSTEM.
• EFFICIENCY OF THE CONDITIONER IS VALID ONLY AT THE STATED SALT DOSAGE.
IMPORTANT NOTICE
READ THIS PERFORMANCE DATA SHEET AND COMPARE
THE CAPABILITIES OF THIS UNIT WITH YOUR ACTUAL
WATER TREATMENT NEEDS. IT IS RECOMMENDED THAT
BEFORE PURCHASING A WATER TREATMENT UNIT, YOU
HAVE YOUR WATER SUPPLY TESTED TO DETERMINE YOUR
ACTUAL WATER TREATMENT NEEDS.
30
EC5 75 CV
DEMAND INITIATED TREATMENT SYSTEM
USEPA
MCL
2 PPM
5 PCI/L
AVERAGE EFFLUENT LEVEL
335 PPM
8 PPM
DEMAND INITIATED
WATER TREATMENT SYSTEM
PERFORMANCE DATA SHEET
CAPACITY AND SALT SETTINGS
CAPACITY
9,900 GRAINS
21,300 GRAINS
26,100 GRAINS
THE SYSTEM SHOULD BE INSTALLED IN AN AREA NOT
AFFECTED BY EXTREME HEAT, COLD, OR THE ELEMENTS.
THIS SYSTEM MUST BE INSTALLED IN ACCORDANCE WITH ALL
APPLICABLE STATE AND LOCAL LAWS AND REGULATIONS.
DO NOT INSTALL SYSTEM WHERE WATER IS MICROBIOLOGI-
CALLY
UNSAFE
OR
OF
ADEQUATE DISINFECTION BEFORE OR AFTER THE SYSTEM.
THE SYSTEM CONTAINS AN ION-EXCHANGE MEDIA FOR
REMOVING LISTED CONTAMINANTS AND MUST BE REGENER-
ATED PERIODICALLY. PLEASE REFER TO THE OWNERS MANUAL
TO DETERMINE THE FREQUENCY OF REGENERATIONS.
PLAIN, WHITE BLOCK SALT IS RECOMMENDED FOR THIS
SYSTEM. IF BLOCK SALT IS NOT AVAILABLE, A CLEAN, COARSE
OR EXTRA COARSE ROCK OR SOLAR SALT MAY BE USED. DO
NOT USE GRANULATED SALT. CONSULT YOUR RAINSOFT
DEALER FOR POTASSIUM CHLORIDE USE.
YOUR LOCAL DEALER IS AVAILABLE FOR SERVICE AND
WARRANTY PART REPLACEMENTS.
SEE THE OWNERS MANUAL FOR GENERAL OPERATION AND MAINTE-
NANCE REQUIREMENTS.
SEE WARRANTY CARD FOR SPECIFIC WARRANTY INFORMATION.
TESTED AND CERTIFIED BY THE WQA TO NSF/ANSI
STANDARD 44 FOR THE SPECIFIC PERFORMANCE
CLAIMS AS VERIFIED AND SUBSTANTIATED BY TEST
DATA
TESTED AND CERTIFIED BY THE WQA TO NSF/ANSI
STANDARD 372 FOR LOW LEAD COMPLIANCE
THE EC5 SERIES IS TESTED AND CERTIFIED BY
WQA TO CSA B483.1 STANDARD.
SALT
@ 2.25 LBS. OF SALT
@7.5 LBS. OF SALT
@ 11.2 LBS. OF SALT
UNKNOWN
QUALITY
WITHOUT