Technical Data; Safety Instructions; Specified Conditions Of Use - Milwaukee VP 6 Manual Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18

TECHNICAL DATA

Vacuum pump
Production code
Frequency
Connecting lead
No-load speed
Fuse
Final vacuum
Delivery rate
Dimensions(LxWxH)
Ambient temperature
Compressed air connection
Weight according EPTA-Procedure 01/2003
Motor
D GB
Protection category I (protective earthing), Protection Class IP 54
thermal overload protection
Noise information
Typically, the A-weighted noise levels of the tool are:
Sound pressure level (K=3dB(A))
Wear ear protectors!
The noise level when working can exceed 80 dB (A).
WARNING! Read all safety warnings and all instruc-
tions, including those given in the accompanying bro-
chure. Failure to follow the warnings and instructions may result
in electric shock, fire and/or serious injury. Save all warnings
and instructions for future reference.

SAFETY INSTRUCTIONS

First check whether the mains voltage corresponds to the voltage
given on the power rating plate of the vacuum.
The vacuum should be plugged into approved earthed wall
sockets only. It is forbidden to disconnect the protective ground
contact.
Regularly check the connecting lead and any extension cable for
damage.
Check the hose line for damage, use proper suction hoses, tempe-
rature resistance of at least 80°C.
Please note that electrical devices must be repaired, serviced and
examined by electricians only in accordance with the national
regulations (e.g. in compliance with VBG 4), since improper repairs
can pose significant hazards to the user.
Use original replacement parts only.
No responsibility is accepted for damage incurred as a result of
disregarding the operating instructions, using the device for a use
other than the intended use, and as a result of improper repairs
and utilization.
The intended use is governed by the national work safety regulati-
ons (e.g. Appliance/Equipment Safety Law).
The relevant national accident prevention regulations are to
be observed when commissioning, operating and servicing the
vacuum.
English
Deutsch
8
VP 6
(110 V)
4108 90 02...
... 000001-999999
60 Hz
400 W
3400 U/min
2 AT
-850 mbar
6 m
/h
3
100 l/min
325 x 210 x 280 mm
-10°C – +40°C
IG 3/8 "
12 kg
78 dB (A)
The vacuum must always be used in conjunction with suitable
equipment.

SPECIFIED CONDITIONS OF USE

The vacuum should be set up so that the intake and exhaust
air of the motor has good circulation, and so that the vacuum
does not wander, e.g. due to vibration. Keep the air vents on the
housing unblocked and clean at all times. The vacuum must not
be operated in a closed cabinet unless the cabinet is sufficiently
cooled and ventilated. Please pay attention to the protection class
of the device!
START-UP
Connect the suction hose to the designated connector. Please
make sure that the suction hose used can withstand temperatures
above 80 °C.
Connect the mains cable.
Turn on the device at the main switch.
VP 6
(220-240 V)
4118 61 02...
... 000001-999999
50-60 Hz
250 W
3400 U/min
2 AT
-850 mbar
6 m
/h
3
100 l/min
365 x 230 x 268 mm
-10°C – +40°C
IG 3/8 "
12 kg
78 dB (A)

Publicidad

Tabla de contenido
loading

Tabla de contenido