setting radio id
Where more than one pellet stove is in use in a dwelling, a different receiver/thermostat kit can be paired. In this
instance, the radio ID code needs to be configured to pair the kit to the correct pellet stove.
After installing and following the instructions in the first installation - thermostat configuration chapter, follow
these instructions:
Disconnect the receiver;
Access the thermostat via settings - radio id channel;
Select a different radio id setting;
Power up the receiver (yellow LeDs will flash on the receiver) and confirm the selected unit on the thermostat
within 10 seconds . Once the configuration has been carried out correctly, the yellow LeDs will stay on stable
for a few seconds.
eXample setting with more than one thermostat
ducted pellet stove
The pellet stove must have electronic ducting management, not mechanical. 2 thermostats can be paired (optional) together with
the receiver/thermostat kit.
Correct configuration for each thermostat:
thermostat 1 setting
Configuration: function - fan duct -
stove temp;
The thermostat replaces the room
sensor of the stove.
thermostat 2 setting
Configuration: function - fan duct -
z1 temp;
The
thermostat
controls
temperature in the ducting Z1.
28
thermostat 2 setting
Configuration: function - fan duct -
z2 temp;
the
The
thermostat
temperature in the ducting Z2.
controls
the