Additional Installation Tips - SolarVenti SV14 Manual De Instalación

Ocultar thumbs Ver también para SV14:
Tabla de contenido

Publicidad

Basement Installation manual 
UK 
Additional installation tips 
 
 
 
 
 
 
INTRO 
All  measurements  in  this  manual  are  applicable  to  the  SolarVenti  (K)  basement 
 
models only. The measurements CANNOT be used with our standard SolarVenti air 
 
collectors (SV14, SV20, SV30). 
 
 
 
Optimal Inblow: If possible the air inlet should be installed in the driest room and 
 
the outlet in the most humid room in the basement – otherwise you risk spreading 
 
the humid air throughout the entire basement. 
 
 
 
Self‐Cleaning Principle: Self‐cleaning of the felt is started by turning off the system 
 
in bright sunlight at least once a year. After a few hours the felt will be clean from 
 
organic dust particles etc. and the solar air collector can be used again. 
 
 
 
 
TOOLS
The wall of the basement: Drilling through basement walls can be challenging and 
 
 
the tools needed to make the hole will depend on the wall material. Contact your 
 
local SolarVenti installer for further advice regarding the drilling and the installation.  
 
 
 
The hole: Take care not to drill into cables etc.  
 
The centre of the air inlet must be at least 100 mm below the basement ceiling.  
 
The optimal diameter of the hole is Ø133 mm on the inside and Ø140 mm on the 
 
outside. It is possible to use a Ø135 mm both inside and outside. 
 
 
 
Screws:  Screws  for  the  mounting  of  the  Solar  Air  Collector  to  the  wall  are  not 
 
included. 
 
 
p. 6, 12,       
Cable: The cable of the Solar Air Collector may either go through the hole of the air 
20, 22 
inlet – as shown above – or a separate 6‐8 mm hole may be drilled in the position 
 
desired. 
 
 
p. 8 
Insulation: Insulation of the pipe is needed. An insulation matt and aluminium cover 
 
can be purchased from SolarVenti A/S. 
 
 
p. 8, 14 
Stands:  Drill  two  holes  in  each  rack  and  mount  them  to  the  wall  with  suitable 
 
screws.  
 
 
p. 10 
Angle: Find the reference point       of the Solar Air Collector's connection pipe. Mark 
 
the  grey  area  on  the  wall  to  indicate  the  position  of  the  air  inlet  hole  where  the 
 
drilling  can  be  made.  (Please  note  that  an  Extra  Extension  Kit  will  extend  the 
 
maximum length from 1010 mm to 2010 mm). 
 
If you want to use the total length of the pipe G, you have to drill the hole on the 
 
bottom line. If you drill a hole in the grey area, you will have to cut the pipe. 
 
 
 
 
 
 
SolarVenti ®     www.solarventi.com   
IX. Additional installation tips