Fault Code; 3-10.Warning Indicator; 3-11.Warning Code - SHT 10K Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3-9. Fault Code

Fault code
Fault event
01
Bus start failure
02
Bus over
03
Bus under
04
Bus unbalance
06
Converter over current
11
Inverter soft start failure
12
High inverter voltage
13
Low inverter voltage
14
Inverter A output(line to
neutral) short circuited
15
Inverter B output(line to
neutral) short circuited
16
Inverter C output(line to
neutral) short circuited
17
Inverter A-B output (line
to line) short circuited
18
Inverter B-C output (line
to line) short circuited
19
Inverter C-A output (line
to line) short circuited

3-10.Warning Indicator

Warning
Battery low
Overload
Battery unconnected
Over charge
EPO enable
Fan failure/Over temperature
Charger failure
I/P fuse broken
Overload 3 times in 30min

3-11.Warning Code

Warning code
Warning event
01
Battery unconnected
Icon
Fault code
None
1A
None
1B
None
1C
None
21
None
24
None
29
None
31
None
36
41
42
43
46
47
48
Icon (flashing)
Warning code
10
27
Fault event
Inverter A negative power fault
Inverter B negative power fault
Inverter C negative power fault
Battery SCR short circuited
Inverter relay short circuited
Battery fuse broken in Battery
mode
Parallel communication failure
Parallel output current
unbalance
Over temperature
DSP communication failure
Overload
Incorrect UPS setting
MCU communication failure
Two DSP firmware versions are
incompatible.
Alarm
Beeping every second
Beeping twice every second
Beeping every second
Beeping every second
Beeping every second
Beeping every second
Beeping every second
Beeping every second
Beeping every second
Warning event
L1 IP fuse broken*
Icon
None
None
None
None
None
None
None
None
None
None
None
None
None

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

10kl15k15kl20k20kl30k ... Mostrar todo

Tabla de contenido