Technical Specifications - GiBiDi SC24 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
SC24

TECHNICAL SPECIFICATIONS

Control unit
Type
Power supply
No. of motors
Motor power supply
Flashlight
Warning light
Accessory power supply
Safety device power supply
Plug-in
Operating temperature
Run time
Pause time
Recommended battery type
FEATURES / FUNCTIONS
•Red warning LEDs of N.C. contacts (photo, safety dev, fcc, fca, stop).
•Green warning LEDs of N.O. contacts. (start, ped).
•Safety tests run before the opening and closing movements.
•Deceleration during opening and closing controlled by 2 supplementary magnets to be fitted in the desired position
at a minimum distance of at least 400 mm with respect to those used as limit switch (Fig.2). Deceleration is
adjustable with a trimmer (SLOW).
•Stop and motion inversion for 2 seconds after intervention of the safety devices. At the next Star t pulse the motion
restarts in the obstacle freeing direction.
•Amperometric reading of motor absorption for the anti-crushing function both during normal operation and in slow
motion. (adjustable with AMP .FORCE and AMP .SLOW trimmers). The amperometric intervention determines
stopping and motion inversion for 2 seconds. At the next Start pulse the motion restar ts in the obstacle freeing
direction.
•Pedestrian operation with fixed opening of 10 seconds. The condominium function and automatic closing are
always enabled.
•Provision for use with buffer batteries (accessory battery charger board)
•Test of battery charge status. During battery operation, an acoustic signal synchronised with the flashlight will be
activated. When the batteries are nearly flat and an opening command is given, the gate will open and remain thus.
Should the batteries not be sufficiently charged, the gate will not open.
SAFETY DEVICE POWER SUPPLY. Connection to this power supply allows TESTING the devices before motion. The
safety devices must be connected to this terminal and will be powered only during the operating cycle.
Electronic control unit for automation of a sliding gate with
230Vdc single-phase 50/60 Hz
24Vdc 8W max including safety device power supply
24Vdc 8W max including accessory power supply
Adjustable between 2 and 215 sec.
Rechargeable lead battery 24V 2Ah (2 x 12V 2Ah)
SC24
24Vdc motor
1
24Vdc
24Vdc 10W max
24Vdc 3W max
Radio receiver
-20°C +60°C
240 sec. fixed
9
UK

Publicidad

Tabla de contenido
loading