Notices:
• The compressor has been set so that it starts functioning three minutes after the
(re)start of the air conditioner.
• The cooling will switch off when the room temperature is lower than the set
one. Ventilation will however continue to work on the set level. When the room
temperature rises above the selected value, the cooling will work again.
EMPTYING THE INTERNAL WATER CONTAINER
When the water container is full, the compressor stops but the ventilator keeps
functioning, LED [4]
Switch off the unit and remove the plug from the mains.
• Place the water tray flat on the floor under the drain.
• Remove the drain knob.
• Remove the rubber plug and fill the water tray then
replace the plug to stop the water flow. Empty the
tray and repeat this process until all water has been
removed.
• Replace the rubber plug and the drain knob, plug
the unit in and switch on. The LED [4]
now be out.
PERMANENT DRAINAGE
Switch off the unit and remove the plug from the mains.
• Remove the drain knob and the rubber plug.
• Connect the correct water tube onto the water outlet.
• Place the other end in a normal drain.
• Make sure that the tube is free from twists and bends.
The tube must incline over its entire length.
Dehumidification
If the unit will be used mainly as dehumidification, do not
connect the exhaust hose and let the warm air return in the
room. Continuous drainage is then convenient and more
efficient.
will be on.
Rubber plug
should
GB
Water tray
Drain knob
7