ELECTRICAL CONNECTIONS: TERMINAL BOARDS
Output - OPENS motor 1
1
(motor to be used for pedestrian gate) *
COMMON output - motor 1
2
(motor to be used for pedestrian gate) *
Output - CLOSES motor 1
3
(motor to be used for pedestrian gate) *
4
Output – OPENS motor 2
5
COMMON output - motor 2
6
Output – CLOSES motor 2
IF DIP 9 OFF = PHASE output for COURTESY
LIGHT (+2 minutes after run time)
7
IF DIP 9 ON= Fixed output
for FLASHLIGHT code 70106
IF DIP 9 OFF = NEUTRAL output for
COURTESY LIGHT (+2 minutes after run time)
8
IF DIP 9 ON= Fixed output
for FLASHLIGHT code 70106
9
LINE INPUT 230 V ~ NEUTRAL
10
LINE INPUT 230 V ~ PHASE
11
GROUND
12
GROUND
COMMON for FA1-FC1-FC2-FA2- inputs
13
of PHOTOCELL
14
LIMIT SWITCH input - closes motor 2 (NC)
The motor capacitor is connected between terminals 1-3 (Motor 1) and 4-6 (Motor 2).
* If the system controls a double-gate system with phase shift (V3 turned clockwise), motor 1 starts opening two
seconds before motor 2, while during closing it starts the mouvement with the delay set by adjusting trimmer
V3.
15
LIMIT SWITCH input-opens motor 2 (NC)
16
LIMIT SWITCH input-closes motor 1(NC)
17
LIMIT SWITCH input-opens motor 1 (NC)
18
PHOTOCELL input (NC)
19
START input (NO)
24 Vac output for power supply of
20
PHOTOCELLS and ACCESSORIES (max. 8W)
(2 pair of photocells + radio receiver)
Common output (0 Vac) for power supply of
21
PHOTOCELLS, ACCESSORIES and
ELECTRIC LOCK
22
12 Vac output for ELECTRIC LOCK (max. 15W)
STOP input (NC; if not used connect with
23
jumper to terminal 25)
Input for PEDESTRIAN GATE START
24
(NA, acts on motor 1)
COMMON input for STOP-START-START
25
PEDESTRIAN GATE
26
ANTENNA CORE input
27
ANTENNA BRAID input
Relay clean-contact to:
- connect a flashlight with fixed light (code
70107) drawing power from the terminals 7 and
28
8 (the relay flashes fast during opening and
-
slowly during closing). Control a warning light
29
to signal gate movement.
- connect a 24 Vac lamp powered by terminals
20-21 (max. 1Watt)