Technical Characteristics - Uponor R-56 Manual De Instalación Y Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
UK

Technical characteristics

Electrical protection Receiver Class II - IP30
Power supply
230 V AC +10/-15%, 50 Hz
Connection
8 points screw connector on the bottom of
the receiver
• 1 relay free contact for remote control
• 2 Inputs for external system
• 1 free contact for external sensor
Operating and
• operating temperature range: 0°C to +50°C
storage conditions
• operating humidity range: 0%RH to 70%RH
• storage temperature range: -20°C to +65°C
• storage humidity range: 0%RH to 80%RH
Certifications
CE. EN 300220-3, EN 301489
(Radio Frequency certifications)
SMS Setup
Check the SMS function by
sending this text by SMS to the
remote access module R-56:
PASS CONF
Note! You must use capital
letters in all messages to the
remote access module R-56.
You will receive a reply with all
the default parameter values of
your installation:
U P O N O R R E M O T E A C C E S S M O D U L E R - 5 6 - M A N U A L
4
CODE=PASS
REPLY=ON
ALARM1=ON
ALARM2=ON
ALARMTEMP=5
OUTPUT=3
BUZZER=3
HEARTBEAT=0
SMSCOUNTER=0
PHONE=+33600000000
Data
Command description
Sets new password (case sensitive!)
Ssss
Always four characters
Controls if the remote access module R-56 shall
ON-OFF
confirm command or not
ON-OFF
If ON, an SMS is sent when an event occurs
ON-OFF
If ON, an SMS is sent when an event occurs
Defines alarm limit for the house low temperature
N
alarm. 0 will deactivate the alarm
0 -> Controlled only by SMS
1 -> On if ALARM1 is ON
N
2 -> On if ALARM2 is ON
3 -> On if ALARM1 or ALARM2 is on
4 -> On if Alarm Temp is on
N
Not used on remote access module R-56
Sets how often the remote access module R-56
shall send status to receiving mobile-phone, if you
N
set 0 the heartbeat will shut off. Max number of
hours are 9999 hours (416 days)
N
Number of SMS sent.
Sets which phone the remote access module R-56
shall send message to when alarm occurs. Must be
N (Max 14)
set up at the installation of the system.
Note! The phone number must include the country
code number
U P O N O R R E M O T E A C C E S S M O D U L E R - 5 6 - M A N U A L
UK
Default
settings
PASS
ON
ON
ON
5
3
3
0 (NO)
0
-
5

Publicidad