Ac Power Analyser Event Source List; Ac Power Analyser Event Target List; Masterbus Event Data - Mastervolt AC Power Analyser Manual De Utilización

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 83
Menu
Description
Events
Event 1 source
Select an event to serve as Event 1. Range:
Disabled, MPC reduce, MPC stop, Load 20%, 40%,
60%, 80%, 100%, AC present, Voltage low, Voltage
high, Current high, Frequency low, Frequency high.
Event 1 target
Select a device in your system to perform the task if
Event 1 takes place.
Event 1 command Select a command, depending on the device you chose. Select... System dependent.
Event 1 data
Refer to figure 9.
Event 2 to 63
Up to 63 events are configurable on the Power Analyser.

6.2 AC POWER ANALYSER EVENT SOURCE LIST

AC present
Voltage low
Voltage high
Current high
Frequency low
Frequency high
MPC reduce
MPC stop
Load 20%, 40%, 60%, 80%, 100% Load is 20, 40, 60, 80 or 100 % of maximum current

6.3 AC POWER ANALYSER EVENT TARGET LIST

Inverter control
Relay (name)
Relay (name)

6.4 MASTERBUS EVENT DATA

Input
Output
On
Off
Copy
Copy
Invert
Toggle
Figure 9: Event data
EN / AC Power Analyser / February 2011
AC voltage present and within the voltage and frequency limits set (section 6.1)
AC voltage under low limit set (section 6.1)
AC voltage over high limit set (section 6.1)
AC current over high limit set (section 6.1)
AC frequency under low limit set (section 6.1)
AC frequency over high limit set (section 6.1)
Maximum Power Control event to reduce power
Maximum Power Control event to disconnect power
Inverter state control, inverter mode
Shore relay state (with name entered), shore mode
Generator relay state (with name entered), generator mode
Default
Disabled See description (left).
Select... System dependent.
Off
See figure 9.
Input (pulses)
The input can be achieved by operating an on/off
switch.
Output (data)
On changes the status to On at the first signal.
Off changes the status to Off at the first signal.
Copy lets the status follow the input.
Copy Invert lets the status follow the opposite of the
input. Copy is used for dimming too by holding the
pulse switch pressed for a longer time.
Toggle changes the status at the first signal and back
at the second signal. It is used in combination with a
pulse switch.
MASTERBUS FUNCTIONS
Range
Off, On, Copy, Copy Invert, Toggle
13