English:
Page 1 •
Replace EIM cover
Place cover on EIM, then push gently until it snaps into place.
Specifications
Temperature Ranges
• Heat: 40° to 90°F (4.5° to 32°C)
• Cool: 50° to 99°F (10° to 37°C)
Operating Ambient Temperature
• 0° to 120°F (-18° to 49°C)
Shipping Temperature
• -30° to 150°F (-34° to 66°C)
Operating Relative Humidity
• 5% to 90% (non-condensing)
Physical Dimensions
• 4-9/16" H x 6" W x 1-3/8" D
• 116 mm H x 152 mm W x 35 mm D
Français:
Page 6 •
Español:
Página 11
Electrical Ratings
Terminal
W Heating
W2 Heating
W3 Heating
Y Cooling
Y2 Cooling
Aux Auxiliary heat
Aux2 Auxiliary heat
G Fan
O/B Changeover
5
Voltage (50/60Hz) Running Current
20-30 Vac
20-30 Vac
20-30 Vac
20-30 Vac
20-30 Vac
20-30 Vac
20-30 Vac
20-30 Vac
20-30 Vac
0.02-1.0 A
0.02-1.0 A
0.02-1.0 A
0.02-1.0 A
0.02-1.0 A
0.02-1.0 A
0.02-1.0 A
0.02-1.0 A
0.02-1.0 A